2005
DOI: 10.1111/j.1467-2995.2005.00169.x
|View full text |Cite
|
Sign up to set email alerts
|

Comparison between facemask and laryngeal mask airway in rabbits during isoflurane anesthesia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
66
1
3

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 77 publications
(70 citation statements)
references
References 13 publications
0
66
1
3
Order By: Relevance
“…According to our results cobraPLA can also be used in rabbit anaesthesia on the other hand v-gel is found as most advantageous one compared to cobraPLA, and this is the first attempt in this field. LMA is seen as the most disadvantaged one in three different supraglottic airways There are notifications about the quite effectiveness and easiness of LMA applications in rabbit anaesthesia without any complication except cyanosis 9 . Unlike these results, LMA is defined as the hardest applicable supraglottic airway compared with the others and had some complications such as edema, mild cyanosis and haemorrhage in our study.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…According to our results cobraPLA can also be used in rabbit anaesthesia on the other hand v-gel is found as most advantageous one compared to cobraPLA, and this is the first attempt in this field. LMA is seen as the most disadvantaged one in three different supraglottic airways There are notifications about the quite effectiveness and easiness of LMA applications in rabbit anaesthesia without any complication except cyanosis 9 . Unlike these results, LMA is defined as the hardest applicable supraglottic airway compared with the others and had some complications such as edema, mild cyanosis and haemorrhage in our study.…”
Section: Discussionmentioning
confidence: 99%
“…Because of this complication, finding of methods of airway management without using of ET is essential in rabbits anaesthesia, so that FM or some supraglottic airways were used. The FM is frequently used but it has some disadvantages such as insufficiency in airway obstruction, not convenient for rabbit face and cause of anaesthetic gas pollution 9,10 .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the use of this modality can be associated with laryngeal leak of anesthetic gas and gastric tympanism, being ended that additional works would be need to be accomplished with this technique before recommend it for routine use in rabbits 13 .…”
Section: Technique Of Blind Tracheal Intubation In Rabbits (Oryctolagmentioning
confidence: 99%
“…An additional option is to use commercially available supraglottic airway devices. [81][82][83][84][85][86][87] When used, airway management devices should be properly fitted and carefully secured in place. Tape or ties made from plastic tubing, gauze, or other materials are acceptable for this purpose.…”
Section: Airway Managementmentioning
confidence: 99%