Comparison between Ultrasound Assisted Extraction and Microwave Digestion in the Determination of Arsenic in Edible Grains

Abstract: A comparative evaluation of arsenic extraction from grains using ultrasound assisted extraction (UAE) and microwave digestion (MW) was developed. The arsenic determination was carried out using hydride generation coupled to flame atomic absorption spectroscopy (HG-FAAS). The optimal extraction condition indicated for corn was 20% v v -1 of HCl, temperature of 67 °C and sonication time of 30 min. For bean, the optical condition was HNO 3 in a 10% v v -1 , temperature of 25 °C and sonication time of 10 min and f… Show more