2019
DOI: 10.21203/rs.2.9134/v2
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Comparison of anterior segment changes after femtosecond laser LASIK and SMILE using a dual rotating Scheimpflug analyzer

Abstract: Purpose To compare the changes in the anterior segment after femtosecond laser in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE) using a dual rotating Scheimpflug (DRS) analyzer (Galilei®; Ziemer Ophthalmology, Port, Switzerland). Setting Onnuri smile eye clinic, Seoul, South Korea Design Retrospective Method 218 eyes of 109 patients who underwent FS-LASIK or SMILE for myopic correction were retrospectively studied. Ninety-eight eyes of 49 patients who underwent FS-LASIK … Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…Furthermore, the deviation of difference in CCT reduction in FS-LASIK was slightly larger than that in SMILE (28 lm vs. [10]. In Kim et al's study, the CCT reduction was 20.69 ± 8.73 lm in the SMILE group, which was higher than that in the FS-LASIK group, which was 8.37 ± 7.70 lm [11]. Other studies comparing CCT reduction between these two procedures showed results in agreement with those of Kim et al, i.e., more overestimated CCT reduction was found after SMILE than after FS-LASIK [8,9,12].…”
Section: Discussionmentioning
confidence: 81%
See 2 more Smart Citations
“…Furthermore, the deviation of difference in CCT reduction in FS-LASIK was slightly larger than that in SMILE (28 lm vs. [10]. In Kim et al's study, the CCT reduction was 20.69 ± 8.73 lm in the SMILE group, which was higher than that in the FS-LASIK group, which was 8.37 ± 7.70 lm [11]. Other studies comparing CCT reduction between these two procedures showed results in agreement with those of Kim et al, i.e., more overestimated CCT reduction was found after SMILE than after FS-LASIK [8,9,12].…”
Section: Discussionmentioning
confidence: 81%
“…A similar trend of overestimating CCT reduction using the identical excimer laser platform was also reported in previous studies. Supporting evidence has reported that the MEL 80 and MEL 90 excimer laser systems tend to overestimate CCT reduction at 8-31 lm [7,10,11]. Conversely, contradictory results were observed in investigating the consistency on other excimer laser systems, namely, the Allegretto 200 Hz, Visx Star S2, EX500, and Amaris 750S platforms [8,9].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…With late advances, it is possible to measure this value by Pentacam, which maps the whole surface of the cornea [2]. It is an important factor to assess the suitability in refractive surgeries as it is used to exclude patients at risk of postoperative ectasia [3].It is also a measure of the rigidity of the cornea and has an in uence on the precision of intraocular pressure (IOP) estimation by Goldman applanation tonometry (thick corneas offer resistance to it, causing a falsely higher IOP) [4,5].…”
Section: Introductionmentioning
confidence: 99%