2022
DOI: 10.1007/s00261-022-03661-8
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of contrast-enhanced fat-suppressed T1-3D-VIBE and T1-TSE MRI in evaluating anal fistula

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 26 publications
0
4
0
Order By: Relevance
“…In another study by Zhao et al, they compared the CE FS 3D T1-weighted VIBE and FS T1-weighted turbo spin echo (TSE) sequence in characteristics of anal fistula. 18 They concluded that 3D T1 VIBE was more accurate and more valuable than 2D TSE T1 images in the assessment of anal fistula on evaluating the position of internal opening, secondary tracts, and classification of the complex fistula.…”
Section: Discussionmentioning
confidence: 99%
“…In another study by Zhao et al, they compared the CE FS 3D T1-weighted VIBE and FS T1-weighted turbo spin echo (TSE) sequence in characteristics of anal fistula. 18 They concluded that 3D T1 VIBE was more accurate and more valuable than 2D TSE T1 images in the assessment of anal fistula on evaluating the position of internal opening, secondary tracts, and classification of the complex fistula.…”
Section: Discussionmentioning
confidence: 99%
“…They have suggested that FS-T1-3D-VIBE offers greater diagnostic potential when evaluating the location of the internal opening, distance from the anal verge, clarity of the internal opening, and classi cation of stula tracks and complex stulas. 23 In this study, we used the superior m-DIXON sequence on the Philips 1.5 T MRI system to obtain T1WI water images (slice thickness 3 mm, slice spacing − 1.5 mm, voxel size 1 mm × 1 mm × 3 mm) and 3D sequences using the T2WI sequence (slice thickness 2 mm, slice spacing − 1 mm, voxel size 1 mm × 1 mm × 2 mm), resulting in higher-resolution images. The length of the adult anal canal is commonly known to be approximately 2.5 cm.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, imaging of anal fistulas needs to be developed to increase the number of 3D sequences to better assist in clinical quality diagnosis. 3D imaging, with advantages including a higher SNR and reduced imaging time, provides thinner cross-sections and covers larger volumes without operator dependence when obliquely collecting images [ 18 ]. The usefulness of 3D T2WI imaging sequences in rectal cancer and female pelvis has been evaluated [ 24 ].…”
Section: Discussionmentioning
confidence: 99%
“…A paired independent samples t -test was applied to compare the differences in the locations, SNRs, and CNRs between the ACS and control groups. The interrater reliability of the two radiologists was assessed by both weighted Kappa Coefficient [ 18 ] (Kappa value, κ>0.8, excellent agreement; 0.60 ≤ κ ≤ 0.80, good agreement; 0.40 ≤ κ<0.60, moderate agreement; 0.20 ≤ κ<0.40, fair agreement; κ<0.20, poor agreement) and Intraclass Correlation Coefficient [ 19 ] (ICCs, ICC>0.90, excellent agreement; 0.75≤ ICC <0.9, good agreement; 0.5≤ ICC< 0.75, moderate agreement; ICC<0.5, poor agreement). To determine the agreement of correct diagnostic effectiveness between ACS/control MRI and surgical results, the kappa statistic was used and the 95 % confidence intervals (CIs) was obtained.…”
Section: Methodsmentioning
confidence: 99%