2013
DOI: 10.1002/dc.23041
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of diagnostic accuracy between CellprepPlus® and ThinPrep® liquid‐based preparations in effusion cytology

Abstract: Liquid-based cytology (LBC) is being increasingly used for body fluid specimens and has improved diagnostic accuracy when compared to conventional smears. We compared the diagnostic accuracy and cellular morphologic features between CellprepPlus® LBC and ThinPrep® LBC in effusion cytology. One hundred and eighty body fluid specimens, consisting of 119 pleural fluid specimens, 59 peritoneal fluid specimens, and 2 pericardial fluid specimens, were obtained from 166 patients. Equal volumes of body fluid from each… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

4
46
1
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 29 publications
(52 citation statements)
references
References 14 publications
4
46
1
1
Order By: Relevance
“…Several papers highlighted the improvements in the sensitivity and specificity of peritoneal washings from gynecological and gastro-intestinal cancers using a wide range of markers to define either a primary or a metastatic origin [2023]. This adjunct seems to be empowered by the use of a panel of immunomarkers that is more easily applied when LBC is adopted [14]. The well-known controversial data concerning the efficacy of LBC are counter-parted by the reliable and feasible yields, including cost-effectiveness; time-sparing and easy application of ancillary techniques up to 3–4 months on the LBC stored material [15, 24–26, 30, 32, 34].…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Several papers highlighted the improvements in the sensitivity and specificity of peritoneal washings from gynecological and gastro-intestinal cancers using a wide range of markers to define either a primary or a metastatic origin [2023]. This adjunct seems to be empowered by the use of a panel of immunomarkers that is more easily applied when LBC is adopted [14]. The well-known controversial data concerning the efficacy of LBC are counter-parted by the reliable and feasible yields, including cost-effectiveness; time-sparing and easy application of ancillary techniques up to 3–4 months on the LBC stored material [15, 24–26, 30, 32, 34].…”
Section: Discussionmentioning
confidence: 99%
“…This adjunct seems to be empowered by the use of a panel of immunomarkers that is more easily applied when LBC is adopted [14]. The well-known controversial data concerning the efficacy of LBC are counter-parted by the reliable and feasible yields, including cost-effectiveness; time-sparing and easy application of ancillary techniques up to 3–4 months on the LBC stored material [15, 24–26, 30, 32, 34]. Besides, an article by Hoda evaluated all the known literature for the morphological aspects of LBC in non-gynecological cytology as well as the accuracy of both TP and SurePath in the interpretations of effusions in alignment with the data from Ylagan et al [3, 17].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations