2018
DOI: 10.3341/kjo.2017.0091
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Ocular Biometry Using New Swept-source Optical Coherence Tomography-based Optical Biometer with Other Devices

Abstract: PurposeTo evaluate the agreement between optical biometry with swept-source optical coherence tomography-based optical biometry (IOLMaster 700) and other devices.MethodsA total of 137 eyes (78 patients) with cataracts were included in this retrospective study. Axial length (AL), anterior chamber depth (ACD), keratometry, and white-to-white (WTW) distance measured using IOLMaster 700 were compared with results for the following five different biometers: IOLMaster 500, A-scan, automated refractor, manual keratom… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
27
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(27 citation statements)
references
References 17 publications
0
27
0
Order By: Relevance
“…A high interclass correlation of 1 when measuring AL between IOLMaster 500 and 700 was observed. The mean difference between ACD measured by the two devices was only 0.08 mm, which is not clinically significant 2,11 . Another study assessed differences between IOLMaster 500 and Scheimpflug based camera Galileli G6 (Zimer, Port, Switzerland).…”
Section: Discussionmentioning
confidence: 72%
See 2 more Smart Citations
“…A high interclass correlation of 1 when measuring AL between IOLMaster 500 and 700 was observed. The mean difference between ACD measured by the two devices was only 0.08 mm, which is not clinically significant 2,11 . Another study assessed differences between IOLMaster 500 and Scheimpflug based camera Galileli G6 (Zimer, Port, Switzerland).…”
Section: Discussionmentioning
confidence: 72%
“…The recent clinical introduction of OCT-based biometers enabled identifying any irregularities in the eye anatomy such as lens tilt, macular edema, or central retinal detachment 11 . In this article, we used this new technology and analyzed the parameters in several significant ways.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…4 The updated IOL Master 700 (Carl Zeiss meditec, Germany) is a popular swept source optical tomography based optical biometer. 5 This SS-OCT is capable of obtaining multiple measurements in a single capture and generate AL abd ACD values with perfect alignation of subject's visual axis. 5 It uses a rapid-cycle, tunable wavelength laser to scan the eye, which improves the tissue penetration and image quality.…”
Section: Introductionmentioning
confidence: 99%
“…5 This SS-OCT is capable of obtaining multiple measurements in a single capture and generate AL abd ACD values with perfect alignation of subject's visual axis. 5 It uses a rapid-cycle, tunable wavelength laser to scan the eye, which improves the tissue penetration and image quality. 6 The ultrasound biometry using 10-MHz ultrasound waves to measure axial length and anterior chamber depth.…”
Section: Introductionmentioning
confidence: 99%