Comparison of TEST 1 with SRS 100 and ICSH reference method for the measurement of the length of sedimentation reaction in blood

Abstract: The findings suggested that TEST 1 is a reliable, precise and accurate system for measurement of LSRB in clinical laboratories with high workload.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
18
0
1

Year Published

2007
2007
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(22 citation statements)
references
References 15 publications
3
18
0
1
Order By: Relevance
“…8 Some of them have the advantage of being automated or semi-automated, having shorter testing times, and/or reducing biohazard exposure during testing as the samples are aspirated from closed tubes. 2,5,7,10,[15][16][17][18][19][20] These alternate methods adopt procedures for measuring rouleaux formation that is distinct from the Westergren or the modified Westergren method, such as centrifugation or photometric rheology. Some studies have shown that the ESR measured by the microhemagglutination method better reflects inflammation than that measured by the Westergren method in malignancies, autoimmune diseases, or infections.…”
Section: Several New Methods For Esr Measurement Became Availablementioning
confidence: 99%
“…8 Some of them have the advantage of being automated or semi-automated, having shorter testing times, and/or reducing biohazard exposure during testing as the samples are aspirated from closed tubes. 2,5,7,10,[15][16][17][18][19][20] These alternate methods adopt procedures for measuring rouleaux formation that is distinct from the Westergren or the modified Westergren method, such as centrifugation or photometric rheology. Some studies have shown that the ESR measured by the microhemagglutination method better reflects inflammation than that measured by the Westergren method in malignancies, autoimmune diseases, or infections.…”
Section: Several New Methods For Esr Measurement Became Availablementioning
confidence: 99%
“…Very few of these publications used the reference method with undiluted EDTA samples (Caswell & Stuart, 1991; Plebani et al. , 1998; Ozdem et al. , 2006) and did not apply the comparison table included in ICSH‐1993.…”
Section: Review Of the Literature: Use Of The Esr Reference And Standmentioning
confidence: 99%
“…, 2001; Happe et al. , 2002; Al‐Fadhli & Al‐Awadhi, 2005; Ozdem et al. , 2006; Osei‐Bimpong, Meek & Lewis, 2007; Mahlangu & Davids, 2008; Shelat, Chacosky & Shibutani, 2008; Alexy, Pais & Meiselman, 2009; Perovic, Bakovic & Valcic, 2010).…”
Section: Evaluation Of New Analysersmentioning
confidence: 99%
“…It is important that while making comparison between Alifax Roller 20LC and standardized method the nature of sample-diluted or undiluted is kept in mind. As most of the automated analyzer use undiluted sample whereas standardized methods can use either diluted or undiluted samples, while comparing two results sample harmony and matrix has to be similar else the conclusion will be invalid [13,14,15] . The newer technologies tend to use undiluted EDTA samples for making them user friendly without the need of transferring samples from EDTA vials to ESR vial for making them user friendly and economical.…”
Section: Discussionmentioning
confidence: 99%