Comparison of the Radial Compliance of Three Kinds of Vascular Prostheses and Pig’s Carotid Based on Dynamic-Simulated Condition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
3

Relationship

3
0

Authors

Journals

citations
Cited by 3 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…Compliance, including circumferential and longitudinal compliance, plays a critical role in maintaining standard hemodynamic stability, especially for small diameter blood vessels which are extremely sensitive to the diameter changes. However, even for a woven PET vascular graft, the circumferential compliance can only reach 0.75% under 80–120 mmHg pressure . Despite this, it is higher than that of a standard commercial ePTFE one, 0.64%, while the circumferential compliance of a native blood vessel is around 5% .…”
Section: Discussionmentioning
confidence: 88%
See 3 more Smart Citations
“…Compliance, including circumferential and longitudinal compliance, plays a critical role in maintaining standard hemodynamic stability, especially for small diameter blood vessels which are extremely sensitive to the diameter changes. However, even for a woven PET vascular graft, the circumferential compliance can only reach 0.75% under 80–120 mmHg pressure . Despite this, it is higher than that of a standard commercial ePTFE one, 0.64%, while the circumferential compliance of a native blood vessel is around 5% .…”
Section: Discussionmentioning
confidence: 88%
“…Despite this, it is higher than that of a standard commercial ePTFE one, 0.64%, while the circumferential compliance of a native blood vessel is around 5% . In addition, a longitudinal strain of 50% was expected for a vascular graft to meet the longitudinal compliance of a native blood vessel . Undoubtedly, current vascular grafts do not meet these clinical requirements regarding high compliance yet.…”
Section: Discussionmentioning
confidence: 95%
See 2 more Smart Citations
“…The suture retention force was tested according to Standard ISO 7198: 1998 [16]. Furthermore, the scaffold's elastic recovery after compression was determined on a Laizhou Electronic Instrument (Model YG061) radial compression apparatus.…”
Section: Characterization Methodsmentioning
confidence: 99%