Comparison of two clean-up principles for determination of trichothecenes in grain extract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
1
4

Year Published

2000
2000
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 49 publications
(32 citation statements)
references
References 21 publications
0
27
1
4
Order By: Relevance
“…C 8 , C 18 ), strong cation or anion exchangers (SCX, SAX) or polymeric materials with combined properties. Modern clean-up procedures employ multifunctional MycoSep Õ (Krska 1998;Radová et al 1998;Biselli and Hummert 2005;Ren et al 2007) or immunoaffinity columns (IAC) (Krska 1998), although these methods are more expensive than conventional clean-up methodologies. MycoSep Õ columns contain a mixture of charcoal, ion-exchange resins and other materials and are suitable for aflatoxins, trichothecenes, ochratoxins, zearalenone, moniliformin and patulin (Romerlabs 2007).…”
Section: Sample Preparation and Clean-upmentioning
confidence: 99%
“…C 8 , C 18 ), strong cation or anion exchangers (SCX, SAX) or polymeric materials with combined properties. Modern clean-up procedures employ multifunctional MycoSep Õ (Krska 1998;Radová et al 1998;Biselli and Hummert 2005;Ren et al 2007) or immunoaffinity columns (IAC) (Krska 1998), although these methods are more expensive than conventional clean-up methodologies. MycoSep Õ columns contain a mixture of charcoal, ion-exchange resins and other materials and are suitable for aflatoxins, trichothecenes, ochratoxins, zearalenone, moniliformin and patulin (Romerlabs 2007).…”
Section: Sample Preparation and Clean-upmentioning
confidence: 99%
“…All the grain samples collected during the period of 1999-2001 were analysed for DON levels using gas chromatography coupled with electron capture detector (GC/ECD) for quantification of the target analyte (Radová et al 1998). Briefly, the homogenised ground cereal sample (10 g) was extracted with 100 ml acetonitrile:water mixture (84:16, v/v) by shaking it for one hour, MycoSep TM 225 SPE cartridge was used for the purification of the crude extract, trifluoroacetanhydride (TFAA) was used for derivatisation of DON prior to the determination.…”
Section: Determination Of Donmentioning
confidence: 99%
“…For DON, nivalenol and T2-toxin, two main types of method are reported; both advise gas chromatography using either and electron capture detector (ECD) or a MS detector [54][55][56][57] . A clean up (Romer Myco-sep) is mentioned by two labs.…”
Section: How To Analyse Them?mentioning