2014
DOI: 10.1002/rcm.7106
|View full text |Cite
|
Sign up to set email alerts
|

Compatibility of highly sulfated cyclodextrin with electrospray ionization at low nanoliter/minute flow rates and its application to capillary electrophoresis/electrospray ionization mass spectrometric analysis of cathinone derivatives and their optical i

Abstract: RATIONALE: Sodium salts of cyclodextrins are commonly used in capillary electrophoresis/mass spectrometry (CE/MS) analysis of illicit drugs and their optical isomers. To avoid the suppression effect of cyclodextrins under electrospray ionization (ESI), the partial filling technique (PFT) is commonly utilized, which has a limited resolution. Low-flow nano-ESI has been shown to reduce the suppression effect of the salts. To test the compatibility of low-flow ESI with a background electrolyte (BGE) containing sod… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
38
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 37 publications
(38 citation statements)
references
References 30 publications
0
38
0
Order By: Relevance
“…For instance, a recent article published by Moini et al. described the application of a low‐flow sheathless nanospray interface on the enantioseparation of illicit drugs by means of the highly sulfated‐γ‐CD. In conventional sheath interfaces, high ion suppression would be expected when using this chiral selector.…”
Section: Strategies To Enhance the Detection Sensitivitymentioning
confidence: 99%
“…For instance, a recent article published by Moini et al. described the application of a low‐flow sheathless nanospray interface on the enantioseparation of illicit drugs by means of the highly sulfated‐γ‐CD. In conventional sheath interfaces, high ion suppression would be expected when using this chiral selector.…”
Section: Strategies To Enhance the Detection Sensitivitymentioning
confidence: 99%
“…Under the experimental conditions used here, methamphetamine isomers, secondary amines, were not separated using (+)‐18‐C‐6‐TCA. It is possible that using another chiral selector, such as a cyclodextrin, would enable the separation of the methamphetamine isomers …”
Section: Resultsmentioning
confidence: 99%
“…In forensic toxicology, CE has been used for the identification of drugs and their metabolites in various body fluids . One advantage of CE is that it allows for the separation of a wide range of compounds usually by simply changing the background electrolyte . Like LC, CE does not require derivatization of analytes and the thermal stability of the compounds is not an issue.…”
mentioning
confidence: 99%
“…This construction is based on 30 μm id emitter constructed from porous glass membrane surrounded by a conductive liquid, providing electrical connection without any noticeable sample dilution. In the pursuit of a stable electrospray at low flow rates, better ionization efficiency and resolution power, Moini investigated possibilities of the instrumentation based on porous emitter with id of 5–20 μm in the applications mentioned elsewhere in this review . Recently, Guo et al.…”
Section: Development Of Methodology and Instrumentationmentioning
confidence: 99%