2006
DOI: 10.1016/j.chroma.2006.08.081
|View full text |Cite
|
Sign up to set email alerts
|

Compliance analysis of phenylurea and related compounds in drinking water by liquid chromatography/electrospray ionization/mass spectrometry coupled with solid-phase extraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
22
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(23 citation statements)
references
References 29 publications
1
22
0
Order By: Relevance
“…In order to determine trace analytes by UV detection method, a sample preparation technique prior to analysis is needed, the most used sample preparation techniques include SPE [3,5,8,[12][13][14], SPME [6,11], LLE [10], LPME [15,16], and DLLME [17]. However, these techniques possess some defects.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to determine trace analytes by UV detection method, a sample preparation technique prior to analysis is needed, the most used sample preparation techniques include SPE [3,5,8,[12][13][14], SPME [6,11], LLE [10], LPME [15,16], and DLLME [17]. However, these techniques possess some defects.…”
Section: Introductionmentioning
confidence: 99%
“…However, derivatization is still necessary for thermally unstable PUHs to be determined by GC. Liquid chromatography (LC) provides the advantage of direct analysis of PUHs, and several detectors have been coupled to LC for the determination of PUHs, including fluorescence [5][6][7], MS [8,9], and UV [10][11][12][13][14]. Among those methods, UV detection offers many advantages, such as low cost, and the absence of labeling process.…”
Section: Introductionmentioning
confidence: 99%
“…Extraction could be also performed with membrane disks containing C 18 -bonded silica (8 μm particles) on polytetrafluoroethylene or glass fiber supports (Spivakov et. al., 2006;Li et al, 2006). Disc provides shorter sample processing time on account of their larger cross-sectional area and decreased pressure drop, allowing higher sample flow rates.…”
Section: Classic Sorbentsmentioning
confidence: 99%
“…High-performance liquid chromatography (HPLC) is preferred with various detection systems including ultraviolet (UV) [20][21][22][23], diode array detection (DAD) [23][24][25][26], MS [27,28] and tandem mass spectrometry (MS n ) [29], and fluorescence detection (FLD) [30]. Generally, LC-MS techniques are considered superior to all the above-mentioned detection techniques, in terms of specificity and sensitivity.…”
Section: Introductionmentioning
confidence: 99%