2010
DOI: 10.1016/j.eurpolymj.2009.09.005
|View full text |Cite
|
Sign up to set email alerts
|

Composition effects on ethylene/propylene copolymers studied by GPC-MALS and GPC-IR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 22 publications
(19 citation statements)
references
References 22 publications
0
19
0
Order By: Relevance
“…Linear PE standards (Polymer Standard Service GmbH, Mainz, Germany), isotactic PP standards (American Polymer Standards, Mentor), linear PE with M w 260 kg/mol, iPP 200 kg/mol, and EP copolymers were dissolved in 1-decanol at a concentration of 1-2 mg/mL at 160 C. Samples of EP copolymers were prepared by Suarez 51,52 and described by Coto et al 53,54 The copolymerization reactions were carried out in a stirred tank reactor operating in semicontinuous mode at 70 C and 5 bar. Their molecular characterization data obtained with high-temperature SEC and NMR spectroscopy are summarized in Table I.…”
Section: Polymer Samplesmentioning
confidence: 99%
“…Linear PE standards (Polymer Standard Service GmbH, Mainz, Germany), isotactic PP standards (American Polymer Standards, Mentor), linear PE with M w 260 kg/mol, iPP 200 kg/mol, and EP copolymers were dissolved in 1-decanol at a concentration of 1-2 mg/mL at 160 C. Samples of EP copolymers were prepared by Suarez 51,52 and described by Coto et al 53,54 The copolymerization reactions were carried out in a stirred tank reactor operating in semicontinuous mode at 70 C and 5 bar. Their molecular characterization data obtained with high-temperature SEC and NMR spectroscopy are summarized in Table I.…”
Section: Polymer Samplesmentioning
confidence: 99%
“…In a previous work [22], obtained values for the q shape parameter range from 0.53 to 0.47 for EP1 and EP19, respectively, using the standard MALS method of calculation. Such slightly dependence with composition was even lower for the rest of studied copolymers.…”
Section: Gpc-malsmentioning
confidence: 99%
“…The molecular weight and molecular weight distribution of the sample were measured using GPC/MALLS (Coto, Suárez, & Caballero, 2007;Liu, Bo, Zhang, & Zhu, 2003;Suárez, Caballero, & Coto, 2010). This process was performed on an infusion system (Waters 515 HPLC Unit Pump) fitted with one gel column (Shodex SB-806M) and the combined detectors (Wyatt-DAWN HELEOS ® eighteen-angle laser light scattering and Wyatt-Optilab rex refractive index detector).…”
Section: Molecular Weight Determinationmentioning
confidence: 99%