2019
DOI: 10.1002/jssc.201900440
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive stability‐indicating high‐performance liquid chromatography coupled with diode array detection method for simultaneous determination of amprolium hydrochloride and ethopabate in powder dosage form for veterinary use

Abstract: This research deals with the development of a stability‐indicating high‐performance liquid chromatography method for simultaneous determination of amprolium hydrochloride and ethopabate. To the best of our knowledge, no comprehensive stability‐indicating method has been reported for analysis of this mixture. Separation was achieved using Kromasil cyano column with gradient elution of the mobile phase composed of sodium hexane sulfonate solution and methanol. Quantification was based on measuring peak areas at … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…According to that, the analytical Eco-Scale value of the developed HPLC-FLD method was found to be 87 indicating an excellent greenness when compared with the score of 77 for the reported HPLC method and 84 for the reported spectroscopic methods (Supporting Information Table S4A-C). This high analytical Eco-Scale score for the proposed method was attributed to replacement of commonly used hazard solvents and chemicals with ACN a less toxic one, which has been used alone as organic modifier in a relatively lower percentage and absence of internal standard, where no extraction or separation step or multistep sample preparation was involved while maintaining good reproducibility of the method [22][23][24][25], as indicated by lower % RSD (Supporting Information Table S2). GAPI [13] is the most recent tool for assessment of greenness of analytical procedure.…”
Section: Assessment Of the Greenness Of The Proposed Methodsmentioning
confidence: 99%
“…According to that, the analytical Eco-Scale value of the developed HPLC-FLD method was found to be 87 indicating an excellent greenness when compared with the score of 77 for the reported HPLC method and 84 for the reported spectroscopic methods (Supporting Information Table S4A-C). This high analytical Eco-Scale score for the proposed method was attributed to replacement of commonly used hazard solvents and chemicals with ACN a less toxic one, which has been used alone as organic modifier in a relatively lower percentage and absence of internal standard, where no extraction or separation step or multistep sample preparation was involved while maintaining good reproducibility of the method [22][23][24][25], as indicated by lower % RSD (Supporting Information Table S2). GAPI [13] is the most recent tool for assessment of greenness of analytical procedure.…”
Section: Assessment Of the Greenness Of The Proposed Methodsmentioning
confidence: 99%
“…The spread of bacteria that are resistant to antibiotics may be facilitated by residual veterinary pharmaceutical drugs in different ecosystem matrices, which may ultimately reduce the clinical or veterinary effectiveness of antibiotics 8 . Several analytical techniques can utilized to determine Amprolium hydrochloride, including UV-spectrophotometry 9,10 , HPLC 11,12 , atomic spectrometry 13 , GC 14 , and other electrochemical methods 15 . Few studies were carried out for the adsorptive removal of AMP from aqueous media 16 .…”
Section: Introductionmentioning
confidence: 99%
“…Literature survey revealed many reported methods for the determination of AMP, SQX, and DVD either alone or with other drugs in different matrices such as veterinary formulation, surface water, eggs, chicken muscles, chicken plasma, chicken liver and chicken feed. These methods include HPLC/UV [4][5][6], LC/MS [7][8][9][10][11][12], spectroscopic methods [13][14][15][16][17][18][19][20] and electrochemical method [21]. To the best of our knowledge, the ternary mixture of AMP, SQX, and DVD has not been investigated spectrophotometrically.…”
Section: Introductionmentioning