2022
DOI: 10.1109/trpms.2022.3166116
|View full text |Cite
|
Sign up to set email alerts
|

Compton and Proximity Imaging of Ac In Vivo With a CZT Gamma Camera: A Proof of Principle With Simulations

Abstract: In vivo imaging of 225 Ac is a major challenge in the development of targeted alpha therapy radiopharmaceuticals due to the extremely low injected doses. In this article, we present the design of a multimodality gamma camera that integrates both proximity and Compton imaging in order to achieve the demanding sensitivities required to image 225 Ac with good image quality. We consider a dual-head camera, each of the heads consisting of two planar cadmium zinc telluride detectors acting as scatterer and absorber… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 56 publications
0
10
0
Order By: Relevance
“…6), indicating that some collimation should be required to provide more accurate position information for reconstruction. Though reduced reconstruction quality, we experimentally demonstrate the feasibility of performing proximity reconstruction with a Compton camera system, as discussed in [30]. How to improve the image reconstruction quality in collimatorless imaging will be investigated in our future studies.…”
Section: Discussionmentioning
confidence: 74%
“…6), indicating that some collimation should be required to provide more accurate position information for reconstruction. Though reduced reconstruction quality, we experimentally demonstrate the feasibility of performing proximity reconstruction with a Compton camera system, as discussed in [30]. How to improve the image reconstruction quality in collimatorless imaging will be investigated in our future studies.…”
Section: Discussionmentioning
confidence: 74%
“…Furthermore, due to the dead stripes in the detector (see figure 7), certain valuable projection data are missing, degrading the image quality. Though reduced reconstruction quality, we experimentally demonstrate the feasibility of performing proximity reconstruction with a Compton camera system, as discussed in Caravaca et al (2022).…”
Section: Hyperparametersmentioning
confidence: 84%
“…Other works have already proposed a Compton camera for the preclinical evaluation of the daughter 221 Bi; 24,25 however, none have demonstrated the feasibility of this modality via experimentation. The most recent study by Caravaca et al 25 simulates the response Previous works have proposed and employed coded apertures for small-animal imaging, 26 but as far as we know, this work is the first to recommend a coded aperture for imaging 221 Fr via its 218-keV emission in small animals. Other analogous collimator-based systems have been employed to image 221 Fr.…”
Section: Discussionmentioning
confidence: 99%
“…Other works have already proposed a Compton camera for the preclinical evaluation of the daughter 221 Bi; 24,25 however, none have demonstrated the feasibility of this modality via experimentation. The most recent study by Caravaca et al 25 . simulates the response of a Compton imager based on CZT.…”
Section: Discussionmentioning
confidence: 99%