2014
DOI: 10.1007/s10891-014-1147-5
|View full text |Cite
|
Sign up to set email alerts
|

Computational Modeling of the Temperature Regime in a Room with a Two-Panel Radiator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…One of the important tasks of room ventilation is the effective organization of air exchange [1] and in particular air distribution [2]. It should provide the air normalized temperature [3], air velocity [4,5], concentration of CO2 [6,7] and other pollutants [8,9] in a room, noise level [10], scent, etc. However, the air stream velocity often exceeds the normalized values.…”
Section: Introductionmentioning
confidence: 99%
“…One of the important tasks of room ventilation is the effective organization of air exchange [1] and in particular air distribution [2]. It should provide the air normalized temperature [3], air velocity [4,5], concentration of CO2 [6,7] and other pollutants [8,9] in a room, noise level [10], scent, etc. However, the air stream velocity often exceeds the normalized values.…”
Section: Introductionmentioning
confidence: 99%
“…Important problems of room ventilation are to ensure both effective organization of air exchange and air distribution [10]. So, the requirements of ensuring of the normalized air velocity and temperature in the premise working area [4,13,14] and energy efficiency [1,28,38,41] should be followed. Heat utilization of exhaust air by recuperators [2,7,37] is often used.…”
Section: Introductionmentioning
confidence: 99%
“…Analysis of literary data has shown that a comfortable state of a person in a premise depends on many factors: air temperature [4,24], air velocity [13], humidity, temperature of the premise surfaces, noise level, thermal resistance of clothing, concentration of CO2 in the premise [15,16], etc. Air distribution schemes are considered and analyzed for being most appropriate to be used indoors, taking into account first of all the attenuation of inflow air jets [6,26,29].…”
Section: Introductionmentioning
confidence: 99%
“…One of the important tasks for arrangement of premises ventilation is creation of the effective organization of air exchange and in particular air distribution (Dovhaliuk, 2018). At the same time, both the normalized air velocity (Tkachenko, 2020) and the normalized temperature (Basok, 2014;Bilous, 2016) in the working area must be ensured.…”
Section: Introductionmentioning
confidence: 99%