2014
DOI: 10.1063/1.4890817
|View full text |Cite
|
Sign up to set email alerts
|

Conception and realization of a parallel-plate free-air ionization chamber for the absolute dosimetry of an ultrasoft X-ray beam

Abstract: We report the design of a millimeter-sized parallel plate free-air ionization chamber (IC) aimed at determining the absolute air kerma rate of an ultra-soft X-ray beam (E = 1.5 keV). The size of the IC was determined so that the measurement volume satisfies the condition of charged-particle equilibrium. The correction factors necessary to properly measure the absolute kerma using the IC have been established. Particular attention was given to the determination of the effective mean energy for the 1.5 keV photo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 32 publications
0
10
0
1
Order By: Relevance
“…In the present case, the substrate is composed of freshly cleaved HOPG foils. The USX source is the Al K α line (1.5 keV) generated by using a lab-bench cold-cathode system (Ounoughi et al, 2013), with a well characterized beam, both spatially and energetically (Groetz et al, 2014), (Ounoughi et al, 2015).…”
Section: Lee Mean Effective Attenuation Length In Dna As Measured Und...mentioning
confidence: 99%
“…In the present case, the substrate is composed of freshly cleaved HOPG foils. The USX source is the Al K α line (1.5 keV) generated by using a lab-bench cold-cathode system (Ounoughi et al, 2013), with a well characterized beam, both spatially and energetically (Groetz et al, 2014), (Ounoughi et al, 2015).…”
Section: Lee Mean Effective Attenuation Length In Dna As Measured Und...mentioning
confidence: 99%
“…The examined dose range was up to 180 kGy. The derivation process of the mean absorbed dose rate in a medium is presented elsewhere (Fullford et al, 1999;Groetz et al, 2014). In the energy region of USX, the photoelectric effect is the main interaction.…”
Section: Methodsmentioning
confidence: 99%
“…Les solutions complexes sont exposées en environnement atmosphérique à la raie Kα de l'aluminium à l'aide d'un générateur de rayons X à cathode froide dont le faisceau a été caracté-risé finement [9,10,11]. Le dispositif complet est schématisé en figure Ultra-Soft X-ray irradiation device.…”
Section: Materiel Et Methodes Dispositif D'irradiation Et Dosimetrieunclassified