Abstract:We report the design of a millimeter-sized parallel plate free-air ionization chamber (IC) aimed at determining the absolute air kerma rate of an ultra-soft X-ray beam (E = 1.5 keV). The size of the IC was determined so that the measurement volume satisfies the condition of charged-particle equilibrium. The correction factors necessary to properly measure the absolute kerma using the IC have been established. Particular attention was given to the determination of the effective mean energy for the 1.5 keV photo… Show more
“…In the present case, the substrate is composed of freshly cleaved HOPG foils. The USX source is the Al K α line (1.5 keV) generated by using a lab-bench cold-cathode system (Ounoughi et al, 2013), with a well characterized beam, both spatially and energetically (Groetz et al, 2014), (Ounoughi et al, 2015).…”
Section: Lee Mean Effective Attenuation Length In Dna As Measured Und...mentioning
“…In the present case, the substrate is composed of freshly cleaved HOPG foils. The USX source is the Al K α line (1.5 keV) generated by using a lab-bench cold-cathode system (Ounoughi et al, 2013), with a well characterized beam, both spatially and energetically (Groetz et al, 2014), (Ounoughi et al, 2015).…”
Section: Lee Mean Effective Attenuation Length In Dna As Measured Und...mentioning
“…The examined dose range was up to 180 kGy. The derivation process of the mean absorbed dose rate in a medium is presented elsewhere (Fullford et al, 1999;Groetz et al, 2014). In the energy region of USX, the photoelectric effect is the main interaction.…”
“…Les solutions complexes sont exposées en environnement atmosphérique à la raie Kα de l'aluminium à l'aide d'un générateur de rayons X à cathode froide dont le faisceau a été caracté-risé finement [9,10,11]. Le dispositif complet est schématisé en figure Ultra-Soft X-ray irradiation device.…”
Section: Materiel Et Methodes Dispositif D'irradiation Et Dosimetrieunclassified
Complexation des acides aminés basiques arginine, histidine et lysine avec l'ADN plasmidique en solution aqueuse : participation à la capture de radicaux sous irradiation X à 1,5 keV
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.