2008
DOI: 10.1093/ejechocard/jen130
|View full text |Cite
|
Sign up to set email alerts
|

Concordance between M-mode, pulsed Tissue Doppler, and colour Tissue Doppler in the assessment of mitral annulus systolic excursion in normal subjects

Abstract: Despite strict correlations exist between M-mode and TD in the assessment of mitral annulus systolic excursion, the effective concordance between techniques is sub-optimal.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
16
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(18 citation statements)
references
References 21 publications
2
16
0
Order By: Relevance
“…We found only moderate associations between AVPDm and TDIs, and they may also not be interchangeable, although TDI correlated well with AVPD in healthy individuals [26,48]. Several possible reasons may explain a lack of correlation between TDI and AVPD [23,49,50]. …”
Section: Discussionmentioning
confidence: 79%
“…We found only moderate associations between AVPDm and TDIs, and they may also not be interchangeable, although TDI correlated well with AVPD in healthy individuals [26,48]. Several possible reasons may explain a lack of correlation between TDI and AVPD [23,49,50]. …”
Section: Discussionmentioning
confidence: 79%
“…It should also be mentioned that the mean longitudinal displacement in the TCA cohort was at the upper limits of established normal values. 28 Accordingly, we have tried not to imply that tortuosity is associated with “hyperdynamic” longitudinal function; only that it is associated with greater longitudinal function as a proportion of the baseline length. Although angiography and echocardiography were not simultaneously performed, we believe that this is a minor limitation since TCA is likely to develop over years to decades.…”
Section: Discussionmentioning
confidence: 99%
“…The two parameters describe different vector components of longitudinal systolic motion. Although TDIs has been described to correlate well with MAPSE in studies with healthy individuals [39,41], they differ in some important aspects [42] as MAPSE measures the entire systolic phase including isovolumetric contraction [15] in contrast to TDIs. In addition a blurred TDI signal can be a confounding factor when measuring the velocity [43] and in these situations MAPSE can be a valuable.…”
Section: Discussionmentioning
confidence: 99%