“…Its effect on surface temperature is quite significant during the day but at night, due to low heat capacity of the plaster layer, the stored heat is quickly lost and the temperature rises only slightly. A similar study, conducted by Fraunhofer-Institute for Building Physics ( Figure 7 ), came to the same conclusions for both emissivity and absorption of short-wave radiation, taking into account the Holzkirchen climate [ 53 , 54 , 55 ].…”
Section: Solutions For Materials Layouts and Building Detailssupporting
confidence: 62%
“…Its effect on surface temperature is quite significant during the day but at night, due to low heat capacity of the plaster layer, the stored heat is quickly lost and the temperature rises only slightly. A similar study, conducted by Fraunhofer-Institute for Building Physics ( Figure 7 ), came to the same conclusions for both emissivity and absorption of short-wave radiation, taking into account the Holzkirchen climate [ 53 , 54 , 55 ].…”
Section: Solutions For Materials Layouts and Building Detailssupporting
confidence: 62%
“…It is necessary to provide the following data for WUFI ® Pro to perform (Figure 1): wall characteristics, physical and hygrothermal material properties, surface transport coefficients, initial conditions, and exterior and interior ambience conditions. The surface orientation and inclination are important inputs of a simulation since the solar radiation and wind-driven rain, if the element is not horizontal, are dependent on these parameters [29,30]. In terms of outputs for the selected assembly, it is possible to assess the temperature ( • C), relative humidity (%), and water vapour partial pressure (hPa) for any of the selected locations within the assembly, water content for any layer (volume, kg/m 3 ) or in terms of equivalent water content for the assembly (area, kg/m 2 ), and the heat (W/m 2 ) and moisture fluxes (kg/m 2 s) for the assembly surfaces and layer interfaces.…”
Section: Wufi Softwarementioning
confidence: 99%
“…According to research [5][6][7] the formation, development and destructive influence of microorganisms on building materials have a direct impact on the living conditions for their existence. For the intensity of the algae growth on the façade, especially humidity, nutrients supply, pH of the environment and peripheral light are required.…”
Section: Risk Of Development Of Biocorrosion In the Composite Structure "Double Etics"mentioning