2022
DOI: 10.1016/j.jelechem.2021.115923
|View full text |Cite
|
Sign up to set email alerts
|

Conductive metal organic framework for ion-selective membrane-free solid-contact potentiometric Cu2+ sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 46 publications
0
4
0
Order By: Relevance
“…The application of MOF-based nanocomposites as a solid contact has been on the rise in recent years, owing to their high electrical conductivity, charge mobility, and surface area. 32,183,184 For the same reasons, MOFs are also widely used as a component of carbon paste in ISEs to improve their sensing performance. For example, 2D Cu-MOF : tricresyl phosphate (TCP) : graphite mixture in a ratio of 2.67 : 30.54 : 66.79 (wt/wt%) was prepared in the form of carbon paste for the detection of Cu 2 , where graphite, 2D Cu-MOF, and TCP acted as the matrix, the electroactive material, and the plasticizer, respectively.…”
Section: Nanocompositesmentioning
confidence: 99%
“…The application of MOF-based nanocomposites as a solid contact has been on the rise in recent years, owing to their high electrical conductivity, charge mobility, and surface area. 32,183,184 For the same reasons, MOFs are also widely used as a component of carbon paste in ISEs to improve their sensing performance. For example, 2D Cu-MOF : tricresyl phosphate (TCP) : graphite mixture in a ratio of 2.67 : 30.54 : 66.79 (wt/wt%) was prepared in the form of carbon paste for the detection of Cu 2 , where graphite, 2D Cu-MOF, and TCP acted as the matrix, the electroactive material, and the plasticizer, respectively.…”
Section: Nanocompositesmentioning
confidence: 99%
“…Subsequently, in 2022, conductive nanoscale polyhedral Cu 3 (HHTP) 2 was fabricated by heating a degassed aqueous solution of Cu(COOCH 3 ) 2 •H 2 O and HHTP at 70 °C for 24 h, with the caps loosely covered. [100] Hydro/Solvothermal Strategy:…”
Section: Direct Reaction In Solutionmentioning
confidence: 99%
“…In another work, Gan, Niu and coworkers further illustrated this ISM-free potentiometric sensing strategy by utilizing the 2D conductive MOF of Cu 3 (HHTP) 2 formed from Cu and 2, 3, 6, 7, 10, 11-hexahydroxytriphenylene (HHTP) as the solid contact bifunctional material to detect Cu(II), without a traditional ISM used. 48 A satisfactory Nernstian and selective response toward Cu(II) detection was disclosed, affording a slope of 29.5 AE 0.3 mV dec À1 . Notably the potentiometric response time was substantially reduced from about 50 s to 10 s. Moreover, the Cu 3 (HHTP) 2based bifunctional solid contact ISE also exhibited a short conditioning time at the minutes level and showed good tolerance toward organic solvents in comparison to the ISE with the ISM.…”
mentioning
confidence: 91%
“…2), with the polymeric ISM removed. [47][48][49] For instance, Gan and coworkers directly utilized Li-ion battery materials of LiFePO 4 and LiMn 2 O 4 for the Li ion recognition via the crystal ion intercalation and applied the fabricated non-membrane solid contact ISE to determine lithium in the human blood serum, giving a good Nernstian response. 47 The interfering ions, particularly Na + , did not have much influence.…”
mentioning
confidence: 99%