2009
DOI: 10.1365/s10337-009-0969-3
|View full text |Cite
|
Sign up to set email alerts
|

Confirmation and Determination of Sugars in Soft Drink Products by IEC with ESI-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 22 publications
0
7
0
Order By: Relevance
“…The column was operated at 30 • C with a flow rate of 0.5 mL/min. Sample injection was 20 L and achieved by use of an autosampler maintained at 4 • C. Conditions for the mobile phases were modified from previous publications [4,11] as follows: A -aqueous solution containing 0.1% acetic acid; B -acetonitrile containing 0.1% acetic acid. Elution began with 90:10 (A:B) for 2 min, increasing linearly to 0:100 over 8 min, isocratic for 3 min at 0:100, decreasing linearly to 90:10 over 3 min and maintained isocratically at 90:10 for 3 min, for a total run time of 17 min.…”
Section: Instrumentation and Acquisition Parametersmentioning
confidence: 99%
See 2 more Smart Citations
“…The column was operated at 30 • C with a flow rate of 0.5 mL/min. Sample injection was 20 L and achieved by use of an autosampler maintained at 4 • C. Conditions for the mobile phases were modified from previous publications [4,11] as follows: A -aqueous solution containing 0.1% acetic acid; B -acetonitrile containing 0.1% acetic acid. Elution began with 90:10 (A:B) for 2 min, increasing linearly to 0:100 over 8 min, isocratic for 3 min at 0:100, decreasing linearly to 90:10 over 3 min and maintained isocratically at 90:10 for 3 min, for a total run time of 17 min.…”
Section: Instrumentation and Acquisition Parametersmentioning
confidence: 99%
“…for GC/MS methods for detection of polar constituents [9,11]. Conversion of target compounds to volatile derivatives for analysis and quantitation using GC/MS is time consuming and potentially damaging to heat labile compounds [11].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…It is highly relevant to emphasize that several researchers, such as Chen et al (2009Chen et al ( , 2010 , using Balfourodendron riedelianum. The reminiscent presence of this carbohydrate indicates that fructose was consumed at a lower rate than glucose during the initial hours of the fermentation assay.…”
Section: Resultsmentioning
confidence: 99%
“…Thus NPLC, contrary to APPI, leads to poor results when it is directly coupled to ESI. By contrast, although salts and ion-pairing agents may cause ion suppression, ion-exchange chromatography (Chen et al , 2009 and ion-pairing reversed-phase liquid chromatography de Person et al 2008) remain sufficiently compatible with ESI-MS. RPLC and HILIC are the most universal LC modes for hyphenation. The only circumspection is to avoid too concentrated buffers for pH or ionic strength control.…”
Section: Interfacing Mass Spectrometry With Separation Techniquesmentioning
confidence: 99%