1973
DOI: 10.1021/ja00785a002
|View full text |Cite
|
Sign up to set email alerts
|

Conformational analysis. I. Molecular structure, composition, trans-gauche energy and entropy differences, and potential hindering internal rotation of gaseous oxalyl chloride as determined by electron diffraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
41
0

Year Published

1973
1973
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 154 publications
(44 citation statements)
references
References 1 publication
3
41
0
Order By: Relevance
“…These authors also find the trans conformer to be the most stable and the torsional potential energy curve to have the same general shape as that shown in Figure 2. The trans-cis energy difference is 13.4 compared with 24.0 kJ mol-' in this study, and the gauche minimum is at 1 3 1 O (trans 0" convention) with a trans-gauche energy difference of 3.3 kJ mol-', compared with a minimum at 130" and an energy difference of 9.5 kJ mol-'.…”
Section: Appendix Estimation Of the Correlation Energy For 23-diaza-mentioning
confidence: 41%
“…These authors also find the trans conformer to be the most stable and the torsional potential energy curve to have the same general shape as that shown in Figure 2. The trans-cis energy difference is 13.4 compared with 24.0 kJ mol-' in this study, and the gauche minimum is at 1 3 1 O (trans 0" convention) with a trans-gauche energy difference of 3.3 kJ mol-', compared with a minimum at 130" and an energy difference of 9.5 kJ mol-'.…”
Section: Appendix Estimation Of the Correlation Energy For 23-diaza-mentioning
confidence: 41%
“…The optical densities were measured with a Joyce Loebl double-beam microdensitometer. The data were reduced in the usual way [27][28][29]. Ranges of data were 2.00 _< s/]k -I <_ 15.00 and4.00 _< silk -I <-30.00 for 1-chlorobutane and 2.00 <_ slY, -~ <_ 15.00 and 4.00 < slY, -I <_ 26.00 for 1-bromobutane and l-iodobutane.…”
Section: Experimental Section and Data Reductionmentioning
confidence: 99%
“…Six diffraction photographs from the long and four from the short nozzle-to-plate distances were used. Optical densities were measured using a Joyce Loeble dou- ble-beam microdensitometer, and the data were reduced in the usual way [15][16][17]. In order to reduce the noise in the data the short camera photographs were traced twice.…”
Section: Experimental Section and Data Reductionmentioning
confidence: 99%