2005
DOI: 10.1016/j.jvolgeores.2005.01.004
|View full text |Cite
|
Sign up to set email alerts
|

Constraints on dacite magma degassing and regime of the June 15, 1991, climactic eruption of Mount Pinatubo (Philippines): New data on melt and crystal inclusions in quartz

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
39
2

Year Published

2006
2006
2019
2019

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 31 publications
(45 citation statements)
references
References 33 publications
4
39
2
Order By: Relevance
“…Detailed descriptions of melt inclusion types before and after homogenization experiments and of the experimental procedures are given in Borisova et al (2005) along with major element data on the included glass and crystalline phases. The experimental run duration of 20-24 h was chosen according to the diffusion rates of H 2 O and CO 2 in silicic glasses (Watson, 1994) to produce homogeneous glasses in the melt inclusions.…”
Section: Melt Inclusion and Matrix Preparation For Analysesmentioning
confidence: 99%
See 3 more Smart Citations
“…Detailed descriptions of melt inclusion types before and after homogenization experiments and of the experimental procedures are given in Borisova et al (2005) along with major element data on the included glass and crystalline phases. The experimental run duration of 20-24 h was chosen according to the diffusion rates of H 2 O and CO 2 in silicic glasses (Watson, 1994) to produce homogeneous glasses in the melt inclusions.…”
Section: Melt Inclusion and Matrix Preparation For Analysesmentioning
confidence: 99%
“…After the homogenization experiment, quartz grains were mounted in epoxy (Teflon slides, 1-in. diameter) and polished by hand with 3-, 1-and 0.5-lm diamond pastes (Hyprez, Liquid Diamond) until the melt inclusions were exposed at the surface (Borisova et al, 2005). To avoid possible surface contamination with metals like Au, Cu, Zn, As and Sb, we polished quartz grains with pure diamond pastes.…”
Section: Melt Inclusion and Matrix Preparation For Analysesmentioning
confidence: 99%
See 2 more Smart Citations
“…The accuracy of this method is better than ± 0.1 wt%. In addition to SIMS measurements, the H 2 O concentrations of MIs were also estimated by subtracting the measured sum of EPMA data from 100 wt% (Devine et al 1995) using equation (1) of Appendix A in the study by Borisova et al (2005). The use of EPMA data is to fill in the limitation of the SIMS analysis of MIs having diameters smaller than a few tens of m.…”
Section: Analytical Proceduresmentioning
confidence: 99%