2014
DOI: 10.1016/j.enzmictec.2014.02.001
|View full text |Cite
|
Sign up to set email alerts
|

Construction of glutamate biosensor based on covalent immobilization of glutmate oxidase on polypyrrole nanoparticles/polyaniline modified gold electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
22
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 66 publications
(23 citation statements)
references
References 41 publications
0
22
0
1
Order By: Relevance
“…The biosensor was constructed by the immobilized glutamate dehydrogenase on polypyrrole nanoparticles and the polyaniline composite film on an Au electrode. The biosensor exhibited a rapid response time within 3 sec, excellent sensitivity with a detection limit as 0.1 nM, and a wider linear range from 0.02 to 400 µM [62]. Wang et al developed an acetylcholinesterase (AChE) biosensor based on zinc oxide nanoparticles (ZnO-NP), carboxylic graphene (CGR), and Nafion (NF) hybrid modified glassy carbon electrode (GCE).…”
Section: Biosensormentioning
confidence: 99%
“…The biosensor was constructed by the immobilized glutamate dehydrogenase on polypyrrole nanoparticles and the polyaniline composite film on an Au electrode. The biosensor exhibited a rapid response time within 3 sec, excellent sensitivity with a detection limit as 0.1 nM, and a wider linear range from 0.02 to 400 µM [62]. Wang et al developed an acetylcholinesterase (AChE) biosensor based on zinc oxide nanoparticles (ZnO-NP), carboxylic graphene (CGR), and Nafion (NF) hybrid modified glassy carbon electrode (GCE).…”
Section: Biosensormentioning
confidence: 99%
“…Thus, the determination of this compound is extremely important in both clinical and food samples. Various methods have been used to determine glutamate including high performance liquid chromatography (HPLC) ,, capillary electrophoresis , optical ,, and electrochemical techniques . Among the latter methods, a special attention is payed to electrochemical biosensors due to their sensitivity, selectivity and simple operation .…”
Section: Introductionmentioning
confidence: 99%
“…The lowest limit of detection achieved with a glutamate biosensor was fabricated by covalently immobilizing glutamate oxidase onto polypyrrole nanoparticles and polyaniline composite film (PPyNPs/PANI) [20]. Cyclic voltammetry was used to co-electropolymerize the compounds onto the surface.…”
Section: Cross-linkingmentioning
confidence: 99%