1997
DOI: 10.1016/s0968-0160(96)00230-x
|View full text |Cite
|
Sign up to set email alerts
|

Contact pressure and three-dimensional tracking of unresurfaced patella in total knee arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
13
2

Year Published

1999
1999
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(18 citation statements)
references
References 15 publications
3
13
2
Order By: Relevance
“…3,4,11,34,61,63,95 Other studies have found no initial medial movement. 31,76,77 Of the former group, the point at which the medial displacement becomes maximal and the lateral movement begins is highly variable and ranges from 15° to 40° of knee flexion.…”
Section: Normative Datamentioning
confidence: 94%
See 1 more Smart Citation
“…3,4,11,34,61,63,95 Other studies have found no initial medial movement. 31,76,77 Of the former group, the point at which the medial displacement becomes maximal and the lateral movement begins is highly variable and ranges from 15° to 40° of knee flexion.…”
Section: Normative Datamentioning
confidence: 94%
“…3,4,11,23,30,34,61,63,77,95 Most studies agree that this initial medial tilt is then followed by a lateral tilt as knee flexion continues past 30° to 50°, but the amount of this lateral tilt ranges from 0.7° to 8.2°. 11,30 One study, Goh et al, 25 described the opposite pattern of an initial lateral tilt followed by a medial tilt at 60° to 90° of knee flexion, although they did not measure the first 20° of knee flexion.…”
Section: Normative Datamentioning
confidence: 99%
“…Other devices had a metal-backed baseplate with a rotating, asymmetrical high-conforming polyethylene prosthesis [14]. In-vitro studies utilizing pressure-sensitive films showed significantly higher stresses in these designs which exceeded the yield strength on the polyethylene (>12 MPa) [9,14-17]. Furthermore, other studies showed substantial changes in movement of the patella after TKA: An unresurfaced patella moved along a different path in the groove of the femoral component compared to the physiological motion [1].…”
Section: Introductionmentioning
confidence: 99%
“…In contemporary TKA components, while the patellofemoral contact locations have been measured using various techniques [31,32], the effect of the TKA on the function of the quadriceps-patellar tendon-patella complex has not been reported. Further, the patellofemoral contact biomechanics of the knee were not reproduced by the TKAs during flexion [20,[33][34][35]. It is unknown if a physiological quadriceps and patellar tendon ratio could be reproduced in the knee after a TKA implantation.…”
Section: Discussionmentioning
confidence: 99%