2015
DOI: 10.1021/acs.analchem.5b00625
|View full text |Cite
|
Sign up to set email alerts
|

Continuous Nanoflow-Scanning Electrochemical Microscopy: Voltammetric Characterization and Application for Accurate and Reproducible Imaging of Enzyme-Labeled Protein Microarrays

Abstract: The coupling of scanning electrochemical microscopy (SECM) to a continuous nanoflow (CNF) system is accomplished with the use of a microconcentric ring electrode/injector probe. The gold microring electrode encapsulated by a glass sheath is robust and can be beveled and polished. The CNF system, comprising a precision gas displacement pump and a rotary valve, is capable of delivering solution to the center of the SECM probe in the range of 1-150 nL/min. Major advantages of the CNF-SECM imaging mode over the co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(13 citation statements)
references
References 46 publications
0
13
0
Order By: Relevance
“…The enzyme horseradish peroxidase (HRP) was used as the model enzyme for peroxidase activity imaging, as in addition to having an extensive biosensor potential, it is a commonly used tagging enzyme (enzyme label) for antibody or ligand molecules for molecular recognition or signal amplication in immunoassays, protein microarrays and SECM imaging studies. 17,23,[32][33][34] 2. Materials and methods…”
Section: Introductionmentioning
confidence: 99%
“…The enzyme horseradish peroxidase (HRP) was used as the model enzyme for peroxidase activity imaging, as in addition to having an extensive biosensor potential, it is a commonly used tagging enzyme (enzyme label) for antibody or ligand molecules for molecular recognition or signal amplication in immunoassays, protein microarrays and SECM imaging studies. 17,23,[32][33][34] 2. Materials and methods…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the possibility to put whatever is needed in the capillary ensures the versatility of the method. [117] In tip generation/substrate collection mode, SECM enables locally triggering enzymatic activity. This is also possible thanks to combination of a scanning microelectrode and light emitting methods, like fluorescence or ECL.…”
Section: Hybrid Methodsmentioning
confidence: 99%
“…This lead to higher imaging resolution because no interference from other active sites, which causes overlapping of the diffusion layer, was observed, neither interference from the bulk (Figure ). Moreover, the possibility to put whatever is needed in the capillary ensures the versatility of the method …”
Section: Imaging Of Local Redox Activity/mapping Heterogeneitymentioning
confidence: 99%
See 1 more Smart Citation
“…SECM was also coupled to a continuous nanoflow system [124]. The specially designed tip consisted of a capillary injector surrounded by a microring electrode (r = 11.5 µm).…”
Section: Sg-tc Modementioning
confidence: 99%