2014 International Conference on Renewable Energy Research and Application (ICRERA) 2014
DOI: 10.1109/icrera.2014.7016451
|View full text |Cite
|
Sign up to set email alerts
|

Control of active and reactive powers in three phase inverters for grid-tied photovoltaic systems under unbalanced voltages

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 11 publications
0
3
0
Order By: Relevance
“…5 shows a typical control scheme for the grid-connected mode involving a secondary communication-based layer. This section summarises the available literature [14,15,16,17,20,24,26,162,219, on unbalance mitigation in the gridconnected scenario of both single and multiple inverters. A current source inverter (CSI) is proposed in [227] to achieve good performance under unbalance using direct control with reduced sensors and no PLL.…”
Section: Unbalance Mitigation In the Grid-connected Modementioning
confidence: 99%
See 2 more Smart Citations
“…5 shows a typical control scheme for the grid-connected mode involving a secondary communication-based layer. This section summarises the available literature [14,15,16,17,20,24,26,162,219, on unbalance mitigation in the gridconnected scenario of both single and multiple inverters. A current source inverter (CSI) is proposed in [227] to achieve good performance under unbalance using direct control with reduced sensors and no PLL.…”
Section: Unbalance Mitigation In the Grid-connected Modementioning
confidence: 99%
“…An adjustable strategy for eliminating real or reactive power oscillations is described in [292], while Kabiri et al [293] proposed a simplified extraction method for control under unbalances eliminating sequence extraction. A strategy to inject balanced currents to the grid despite the VUs is presented in [20], while Kumar and Mishra [294] proposed an instantaneous symmetrical component theory-based control neutral clamped three-leg VSI for superior unbalance performance. A coordinated control strategy for parallel GCIs is discussed in [295] for peak current limitation, while Yarmohamad et al [296] proposed a four-wire DSTATCOM for unbalance mitigation.…”
Section: Unbalance Mitigation In the Grid-connected Modementioning
confidence: 99%
See 1 more Smart Citation