2007
DOI: 10.1103/physrevb.76.035338
|View full text |Cite
|
Sign up to set email alerts
|

Control of the Casimir force by the modification of dielectric properties with light

Abstract: The experimental demonstration of the modification of the Casimir force between a gold coated sphere and a single-crystal Si membrane by light pulses is performed. The specially designed and fabricated Si membrane was irradiated with 514 nm laser pulses of 5 ms width in high vacuum leading to a change of the charge-carrier density. The difference in the Casimir force in the presence and in the absence of laser radiation was measured by means of an atomic force microscope as a function of separation at differen… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

19
241
0
1

Year Published

2009
2009
2023
2023

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 181 publications
(261 citation statements)
references
References 84 publications
19
241
0
1
Order By: Relevance
“…First, we briefly consider the preparation of the sphere which was done similar to previous experiments. [20][21][22]27,28,39,40,43,44 We used a polystyrene sphere which was glued with silver epoxy (20 × 20 µm 2 spot) to the tip of a triangular silicon nitride cantilever with a nominal spring constant of order 0.01 N/m. The cantilever-sphere system was then coated with a 10 nm Cr layer followed by 20 nm Al layer and finally with a 105 ± 1 nm Au layer.…”
Section: B Sample Preparation and Characterizationmentioning
confidence: 99%
See 2 more Smart Citations
“…First, we briefly consider the preparation of the sphere which was done similar to previous experiments. [20][21][22]27,28,39,40,43,44 We used a polystyrene sphere which was glued with silver epoxy (20 × 20 µm 2 spot) to the tip of a triangular silicon nitride cantilever with a nominal spring constant of order 0.01 N/m. The cantilever-sphere system was then coated with a 10 nm Cr layer followed by 20 nm Al layer and finally with a 105 ± 1 nm Au layer.…”
Section: B Sample Preparation and Characterizationmentioning
confidence: 99%
“…26 Keeping in mind the applications to micromachines, it is important to control both decreases and increases in the force magnitude. For this purpose, the difference in the Casimir force between a Si plate and an Au sphere was measured 27,28 in the presence and in the absence of 514 nm Ar laser light on the plate. The respective increase in magnitude of the Casimir force by a few percent was observed when the plate is illuminated with laser pulses.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…For dielectric test bodies the theoretical predictions were found in agreement with the data only if the contribution of free charge carriers is omitted [33][34][35][36][37][38]. Keeping in mind that many of the experiments mentioned above were used, first, to make a selection between different theoretical approaches and, second, to constrain corrections to Newtonian gravity from the measure of agreement between the data and the predictions following from a selected approach, the constraints obtained were sometimes claimed to be of dubious merit [39].…”
mentioning
confidence: 99%
“…In the optical modulation experiment [46,47], where a Si plate was radiated with laser pulses, the free charge carrier density n fc in the absence of a pulse was much smaller than the critical concentration at which Si becomes metallic. As a result, the contributions of free charge carriers in the absence and in the presence of laser light were quite different.…”
Section: Introductionmentioning
confidence: 99%