2015
DOI: 10.1016/j.pan.2015.06.005
|View full text |Cite
|
Sign up to set email alerts
|

Conventional versus contrast-enhanced harmonic endoscopic ultrasonography-guided fine-needle aspiration for diagnosis of solid pancreatic lesions: A prospective randomized trial

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
66
0
2

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 76 publications
(68 citation statements)
references
References 29 publications
0
66
0
2
Order By: Relevance
“…A recent published study revealed that CEH-EUS guided FNA has a better accuracy [25]. Moreover, fewer needle passes are required to obtain samples [26].…”
Section: Discussionmentioning
confidence: 99%
“…A recent published study revealed that CEH-EUS guided FNA has a better accuracy [25]. Moreover, fewer needle passes are required to obtain samples [26].…”
Section: Discussionmentioning
confidence: 99%
“…Early comparative results are summarized in Table 2. While early series have not shown any improvement in diagnostic accuracy or sensitivity with the use of CEUS in endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) for pancreatic lesions, Sugimoto et al 2015 described increased interventional efficiency with the use of CEUS-EUS-FNA compared with EUS-FNA (by percent of samples demonstrating sufficiency with a single needle pass, 60% vs. 25%, N = 20 vs. 20, P < 0.05) [26]. …”
Section: Image Guidance For Interventional Proceduresmentioning
confidence: 99%
“…[18][19][20] As CEH-EUS exhibits superior visualization of detecting small lesions compared to traditional EUS, it may assist in pinpointing an appropriate target to increase tissue yield for EUS-FNA. 20,21 Sugimoto et al 22 reported that CEH-EUS-guided FNA was significantly superior to conventional EUS-FNA in obtaining an adequate sample on a single needle pass (60% compared to 25%; P = 0.027). This was attributable to improved visualization of SPL such that samples obtained via CEH-EUS-guided FNA were obtained from areas without fibrosis and necrosis.…”
Section: Contrast-enhanced Harmonic Eusmentioning
confidence: 99%
“…This was attributable to improved visualization of SPL such that samples obtained via CEH-EUS-guided FNA were obtained from areas without fibrosis and necrosis. 22 Although exceedingly rare, reports of tumor seeding following EUS-FNA with multiple needles passes have been reported; thus, CEH-EUS-guided FNA may further diminish this risk by minimizing the number of passes.…”
Section: Contrast-enhanced Harmonic Eusmentioning
confidence: 99%