2013
DOI: 10.1007/s00450-013-0246-4
|View full text |Cite
|
Sign up to set email alerts
|

CoolEmAll—optimising cooling efficiency in data centres

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…Current data-centre modelling programs focus on either data-centre room airflow management or cooling-system simulation, with models designed only for limited, specific applications [25]. More specifically, energy-modelling software has been developed for data-centre simulations such as Project CoolEmAll in March 2013 commissioned by the EU-designed to be the first data-centre simulation tool using a thermal airflow simulation and coupled workload [26].…”
Section: Modelling Data Centres: Advantages Limits and The Gapmentioning
confidence: 99%
“…Current data-centre modelling programs focus on either data-centre room airflow management or cooling-system simulation, with models designed only for limited, specific applications [25]. More specifically, energy-modelling software has been developed for data-centre simulations such as Project CoolEmAll in March 2013 commissioned by the EU-designed to be the first data-centre simulation tool using a thermal airflow simulation and coupled workload [26].…”
Section: Modelling Data Centres: Advantages Limits and The Gapmentioning
confidence: 99%
“…Due to its significant importance, cooling optimization has been the subject of studies done within a number of research and development projects. One of them was CoolEmAll [274,299] which involved several authors of the current paper and investigated how cooling, heat transfer, IT infrastructure, and applications influence the overall energy and cooling efficiency of data centers. CoolEmAll provided advanced planning and optimization tools -SVD Toolkit (Simulation, Visualization and Decision support toolkit) enabling analysis and optimization of data center infrastructure in a holistic manner.…”
Section: Electrical Load Simulation and Predictionmentioning
confidence: 99%
“…As noted in [27], the objective of the CoolEmAll project was to enable designers and operators of a data center to reduce its energy impact by combining the optimization of IT, cooling and workload management. For this purpose CoolEmAll investigated in a holistic approach on how cooling, heat transfer, IT infrastructure, and applicationworkloads influence overall cooling-and energy-efficiency of data centers, taking into account various aspects that traditionally have been considered separately.…”
Section: The Coolemall Projectmentioning
confidence: 99%