2022
DOI: 10.1016/j.rser.2021.111861
|View full text |Cite
|
Sign up to set email alerts
|

Coordinated stochastic optimal energy management of grid-connected microgrids considering demand response, plug-in hybrid electric vehicles, and smart transformers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 49 publications
(17 citation statements)
references
References 73 publications
0
17
0
Order By: Relevance
“…A nested optimization problem is solved. The BESS scheduling is solved as a master problem using the discrete dynamic programming approach (DDP) [11]. DR implementation is done using a DDP approach as a slave problem.…”
Section: Solution Approachmentioning
confidence: 99%
See 1 more Smart Citation
“…A nested optimization problem is solved. The BESS scheduling is solved as a master problem using the discrete dynamic programming approach (DDP) [11]. DR implementation is done using a DDP approach as a slave problem.…”
Section: Solution Approachmentioning
confidence: 99%
“…DR implementation is done using a DDP approach as a slave problem. Further, the hourly optimal renewable energy procurement strategy is also solved as a slave problem using the particle swarm optimization (PSO) technique [11]. To manage inequality constraints, a penalty function approach is utilized.…”
Section: Solution Approachmentioning
confidence: 99%
“…The issues of BESS operation and scheduling have been addressed by many researchers [11][12][13][14] but the development and evaluation of the optimal battery size to achieve a cost-effective system with minimal energy loss and minimal excessive energy storage investment outlays are still ongoing [15]. There are various models for finding the optimal power and energy capacity of storage units in distribution networks and for choosing their configuration strategy.…”
Section: Research Problem Statementmentioning
confidence: 99%
“…The energy router with a predefined voltage algorithm and a fuzzy logic controller are proposed respectively in [6] and [7]. A optimal coordinated operation of a AC micro grid is to minimize the cost of operation subject, the system loss also reduces by 29.49%-31.36% in [8]. A renewable integrated IEEE 9 bus system study the effects of load-sharing devices under 6-cycle three-phase fault disturbances in [9].…”
Section: Introductionmentioning
confidence: 99%