2012
DOI: 10.1016/j.ophtha.2011.08.024
|View full text |Cite
|
Sign up to set email alerts
|

Corneal Densitometry as an Indicator of Corneal Health

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

5
138
3
3

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 179 publications
(149 citation statements)
references
References 18 publications
5
138
3
3
Order By: Relevance
“…Previously, some literatures [2,15] reported significantly increase of corneal density with age and some reported contradictory findings [4,16,17]. However, this study observed a significant increase in corneal density of about 2-3 GSU with each increment of a decade of age.…”
Section: Discussioncontrasting
confidence: 59%
“…Previously, some literatures [2,15] reported significantly increase of corneal density with age and some reported contradictory findings [4,16,17]. However, this study observed a significant increase in corneal density of about 2-3 GSU with each increment of a decade of age.…”
Section: Discussioncontrasting
confidence: 59%
“…Mean corneal densitometry in healthy adults has been recently reported as 12.3±2.4 and 19.7±3.9 GSU in two different studies. 6,7 The right and left corneal densitometry values were also found to be highly correlated in a previous study. 7 However, the corneal densitometry of our patient was 18.6 GSU in the affected eye and 15.7 GSU in the fellow eye.…”
Section: Discussionsupporting
confidence: 63%
“…Densitometry of the corneal tissue provides information about the clarity of the cornea. 6 The densitometry output is expressed in GSU and ranged from 0 (no clouding, maximum transparency) to 100 (completely opaque cornea, no transparency). Mean corneal densitometry in healthy adults has been recently reported as 12.3±2.4 and 19.7±3.9 GSU in two different studies.…”
Section: Discussionmentioning
confidence: 99%
“…Corneal densitometry has been studied in some ocular conditions such as bacterial keratitis, 21 Fuchs' endothelial dystrophy, 22 and keratoconus, 23 and following different procedures such as corneal transplant (DALK) 24 or crosslinking for keratoconus. 25 This is the first study of corneal densitometry in patients undergoing refractive surgery with either PRK, LASIK-FS, or ReLEx SMILE, using the latest Oculus Pentacam system software.…”
Section: Discussionmentioning
confidence: 99%
“…Densitometry measurement with the Pentacam system maybe a useful and objective tool for evaluating postoperative corneal transparency. 21 Thus, densitometry measurements will give refractive surgeons an objective measure of the corneal response and haze, allowing these to be monitored over time.…”
Section: Discussionmentioning
confidence: 99%