1986
DOI: 10.1109/tei.1986.348945
|View full text |Cite
|
Sign up to set email alerts
|

Corona Current and Field Profile Underneath Vertical Bipolar HVDC Lines with Bundle Conductors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

1991
1991
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 7 publications
1
6
0
Order By: Relevance
“…This can be attributed to the fact that the applied field changes around the periphery of each subwire and the point having the highest value of the applied field goes at first in corona. It is clear, for example, that at angle ψ = 90° for SWDEP the field is minimum and the corona onset voltage is maximum in agreement with previous findings in corona discharge [16,17]. Previous investigators have treated the corona onset voltage as a constant value.…”
Section: Resultssupporting
confidence: 87%
See 2 more Smart Citations
“…This can be attributed to the fact that the applied field changes around the periphery of each subwire and the point having the highest value of the applied field goes at first in corona. It is clear, for example, that at angle ψ = 90° for SWDEP the field is minimum and the corona onset voltage is maximum in agreement with previous findings in corona discharge [16,17]. Previous investigators have treated the corona onset voltage as a constant value.…”
Section: Resultssupporting
confidence: 87%
“…Most of the attempts reported in the literature were based on some simplifying assumptions [14][15][16][17], among them Deutsch's assumption. According to this assumption, which states that the space charges affect only the magnitude but not the direction of the electric field, equations (14)(15)(16)(17) can be reduced to the differential equations (18)(19)(20)(21)(22) as shown in Appendix A. These equations describe the distribution of the corona values in the interelectrode spacing in the case of the wire-duct electrostatic precipitators with bundle wires as discharge electrodes.…”
Section: Methods Of Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…The electrostatic "eld description around ac, dc and hybrid ac/dc transmission lines have been presented in several papers (Abu-Seada and Nasser, 1972;Sarma and Drogi, 1988;Abdel-Salam and El-Mohandes, 1990;Abdel-Sattar, 1986;Ismail and Abu-Gammaz, 1999;Ismail, 1999;Singer et al, 1974). Abu Seada has applied the CSM and the method of images to calculate the potential gradient of twin cylindrical bipolar conductors with various geometrical parameters (Abu Seada and Nasser, 1972).…”
Section: Introductionmentioning
confidence: 99%
“…The author has not presented the total RMS values of the electric "eld generated from those con"gurations (Sarma and Drogi, 1988). Abdel-Sattar (1986) has reported a method to calculate the lateral distribution of the "eld intensity over ground surface and underneath vertical bipolar HVDC lines. Abdel-Salam has described the "eld around parallel dc and multi-phase ac transmission lines by using charge simulation technique combined with the method of imaging (Abdel-Salam and El-Mohandes, 1990).…”
Section: Introductionmentioning
confidence: 99%