2009
DOI: 10.1590/s0104-42302009000200026
|View full text |Cite
|
Sign up to set email alerts
|

Correlation between the Doppler velocimetry findings of the uterine arteries during the first and second trimesters of pregnancy

Abstract: SUMMARY OBJECTIVES.Evaluate the feasibility of transvaginal uterine artery Doppler examination in the first and second trimesters of pregnancy, establish reference ranges in a Brazilian population and examine the correlation between these Doppler findings. METHODS. Longitudinal prospective study at the antenatal clinic of a tertiary teaching hospital. Uterine artery Doppler examinations were carried out transvaginally at 11 to 14 weeks and 20 to 25 weeks of gestation. Uterine artery mean pulsatility index (PI)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
9
1

Year Published

2010
2010
2017
2017

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 16 publications
(17 reference statements)
1
9
1
Order By: Relevance
“…This mean UtA-PI value was similar to values obtained for the unaffected group in other studies that utilised transabdominal uterine artery Doppler [21][22][23][24][25] . However, our observed mean UtA-PI value was lower than the mean UtA-PI value of 1.6 reported by another study conducted in Brazil that utilised transvaginal uterine artery Doppler to examine 344 pregnancies with normal pregnancy outcomes 26 .…”
Section: Discussioncontrasting
confidence: 93%
“…This mean UtA-PI value was similar to values obtained for the unaffected group in other studies that utilised transabdominal uterine artery Doppler [21][22][23][24][25] . However, our observed mean UtA-PI value was lower than the mean UtA-PI value of 1.6 reported by another study conducted in Brazil that utilised transvaginal uterine artery Doppler to examine 344 pregnancies with normal pregnancy outcomes 26 .…”
Section: Discussioncontrasting
confidence: 93%
“…Regarding the difference in angle of insonation, we believe that the standard position/direction of the uterine artery facilitates a better angle to be obtained by TVS. In a prospective longitudinal study, Doppler of the uterine arteries, using a transvaginal approach, at 11–14 and 20–25 weeks of gestation in 344 normal singleton pregnancies, showed easy identification of the uterine arteries at the level of the internal cervical os; moreover, TVS gave clear waveforms owing to the close proximity of the transducer to the uterine vessel.…”
Section: Discussionmentioning
confidence: 98%
“…However, this approach seems to be difficult to apply to first‐trimester examination. Liao et al also found that measurement at Site B is not applicable to the first trimester and that different techniques should be employed22. First, the uterus is much smaller during the first trimester and sometimes there is no apparent crossover with the external iliac artery to allow appropriate measurement.…”
Section: Discussionmentioning
confidence: 99%