2021
DOI: 10.1016/j.engfracmech.2021.107785
|View full text |Cite
|
Sign up to set email alerts
|

Correlation of load drop and crack initiation criteria in fatigue life experiments of metallic materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…For total strain amplitudes larger than 1 × 10 −2 , it should be noted tha of the present calculations is limited since the Chaboche parameters we For total strain amplitudes larger than 1 × 10 −2 , it should be noted that the reliability of the present calculations is limited since the Chaboche parameters were adjusted for relatively small total strain amplitudes. Further investigations and results of this work are described in more detail in [31].…”
Section: Uncertainties Of Crack Position and Progression On Total Strain Controlled Fatigue Resultsmentioning
confidence: 98%
See 2 more Smart Citations
“…For total strain amplitudes larger than 1 × 10 −2 , it should be noted tha of the present calculations is limited since the Chaboche parameters we For total strain amplitudes larger than 1 × 10 −2 , it should be noted that the reliability of the present calculations is limited since the Chaboche parameters were adjusted for relatively small total strain amplitudes. Further investigations and results of this work are described in more detail in [31].…”
Section: Uncertainties Of Crack Position and Progression On Total Strain Controlled Fatigue Resultsmentioning
confidence: 98%
“…For the description and evaluation of the incident of crack initiation, the transition between a fatigue analysis from the uncracked to the cracked structure where fracture mechanics-based evaluations in the LCF regime of the components considered are essential. Based on the results of the fatigue tests presented here, the specimens were analyzed with respect to the location of crack initiation and the assumption to be made [31]. The changes in the stress amplitudes of the total strain-controlled fatigue tests (e.g., Figure 4a) are related to crack geometries and crack sizes in order to develop an appropriate correlation.…”
Section: Uncertainties Of Crack Position and Progression On Total Strain Controlled Fatigue Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…For example, information regarding the defect density in bulk materials can be obtained via electrical resistance measurement [4,5] and subsurface changes can be sensed via magnetic field sensors [6,7], resulting in a gain in information. It should be noted that numerous developments have been made in sensor technology, whereby physical parameters associated with very localised fatigue damage can also be recorded with high resolution.…”
Section: Introductionmentioning
confidence: 99%