2020
DOI: 10.1016/j.dib.2019.104912
|View full text |Cite
|
Sign up to set email alerts
|

Correlational data concerning body centre of mass acceleration, muscle activity, and forces exerted during a suspended lunge under different stability conditions in high-standard track and field athletes

Abstract: This article reports data concerning the body centre of mass acceleration, muscle activity, and forces exerted during a suspended lunge under different stability conditions. Ten high-standard track and field athletes were recruited to perform one set of 5 repetitions of the following exercises: suspended lunge, suspended lunge-Foam (front leg on a foam balance-pad and the rear leg on the suspension cradles), a suspended lunge-BOSU up (dome side up), and a suspended lunge-BOSU down (dome side down). For each ex… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 7 publications
0
6
0
1
Order By: Relevance
“…The bandwidth of the accelerometer is 500 Hz. The BIOPAC accelerometer has been fully validated and used as the reference sensor in the development of medical devices ( Costa and Fazendeiro, 2014 ; Aguilera-Castells et al, 2020 ; Jacunski and Rafferty, 2020 ). The dimensions are 16 mm long, 17 mm wide, and 8 mm high, which are appropriate for the simultaneous measurement in different body sites.…”
Section: Methodsmentioning
confidence: 99%
“…The bandwidth of the accelerometer is 500 Hz. The BIOPAC accelerometer has been fully validated and used as the reference sensor in the development of medical devices ( Costa and Fazendeiro, 2014 ; Aguilera-Castells et al, 2020 ; Jacunski and Rafferty, 2020 ). The dimensions are 16 mm long, 17 mm wide, and 8 mm high, which are appropriate for the simultaneous measurement in different body sites.…”
Section: Methodsmentioning
confidence: 99%
“…This, however, does not mean that free, open, and public datasets from the domain of SST do not exist. There are already a significant number of them (e.g., [53,[166][167][168][169][170][171]), together with websites that publish sanitized datasets (e.g., [172]), it remains a fact that they are not used enough. If researchers are going to avoid using existing datasets, they should try to ensure publishing as much of their private datasets as possible.…”
Section: Discussionmentioning
confidence: 99%
“…The activity data of both sides of the vastus medialis (VM) and vastus lateralis (VL) were collected by using BIOPAC (MP160, Biopac Systems Inc., Goleta, CA, United States) equipment with excellent reliability (ICC = 0.82-0.96). 23 AcqKnowledge 5.0 software (Biopac Systems, Inc., Goleta, CA, United States) was used on a personal laptop for signal recording and processing of raw data. Before attaching the electrodes, the hair on the selected muscles was shaved, and the skin was cleaned with alcohol.…”
Section: Muscle Activitymentioning
confidence: 99%