Coulometric total carbon dioxide analysis for marine studies: Automation and calibration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
160
0
1

Year Published

1996
1996
2016
2016

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 309 publications
(161 citation statements)
references
References 8 publications
0
160
0
1
Order By: Relevance
“…The bottles were sealed with rubber stoppers and aluminium crimp-seal caps. DIC was measured by coulometric determination of extracted CO2 after Johnson et al (1987). Total alkalinity in each sample was determined by potentiometric titration with hydrochloric acid (0.1 M HC1 in 0.6 M NaC1) after Winn et al (1994) and calculated according to standard procedures described in DOE (1994).…”
Section: Methodsmentioning
confidence: 99%
“…The bottles were sealed with rubber stoppers and aluminium crimp-seal caps. DIC was measured by coulometric determination of extracted CO2 after Johnson et al (1987). Total alkalinity in each sample was determined by potentiometric titration with hydrochloric acid (0.1 M HC1 in 0.6 M NaC1) after Winn et al (1994) and calculated according to standard procedures described in DOE (1994).…”
Section: Methodsmentioning
confidence: 99%
“…, NO 3 -, PO 4 3-, DSi). For DIC, 12 mL of subsample was stored in gastight Excitainers (Labco, UK) spiked with 200 lL saturated HgCl 2 until analysis on a coulometer (CM5012 UIC Coulometrics; precision ± 2 lmol L -1 ) (Johnson et al 1987). Samples for N 2 -Ar measurements were stored at 15°C in submerged 7-mL glass stoppered vials with 100 lL saturated HgCl 2 until analysis on membrane inlet mass spectrometer (Balzers QMS422; precision for N 2 determination ± 0.5 lmol L -1 ) (Eyre et al 2002).…”
Section: In Situ Chamber Incubationsmentioning
confidence: 99%
“…Select bottles were subsampled on deck for analyses of the different chemical parameters. The DIC analyses were performed with a coulometer connected to a Single Operator Multi-parameter Metabolic Analyzer, SOMMA (Johnson et al, 1987), following the procedures outlined in the Handbook of Analysis of Carbon Parameters in Seawater (DOE, 1994). The accuracy of the DIC analyses was estimated at 2 mmol kg À 1 , except for the AJAX cruise of 1983 that preceded the availability of certified reference materials to confirm accuracy.…”
Section: Description Of Cruises and Instrumental Analysesmentioning
confidence: 99%