Coupling Ion Chromatography to Q-Orbitrap for the Fast and Robust Analysis of Anionic Pesticides in Fruits and Vegetables

Abstract: Ion chromatography coupled to a quadrupole Orbitrap mass analyzer was used to develop a multiresidue method for the determination of highly polar pesticides and their metabolites (chlorate, perchlorate, fosetyl-aluminum, glyphosate, aminomethylphosphonic acid (AMPA), phosphonic acid, N-acetyl AMPA, and N-acetyl glyphosate) in fruits and vegetables. After extraction with methanol, samples were diluted 5× with water. No derivatization was applied. Pesticides were separated in an anion-exchange column. Water was … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
27
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 35 publications
(28 citation statements)
references
References 0 publications
1
27
0
Order By: Relevance
“…It was found that the acidity of the extracts influenced the retention times and peak shapes if the QuPPe extracts (extracted with 1% formic acid in methanol) were analysed with < 1 mmol/L mobile phases. Poor recoveries have been reported for acidified QuPPe extracts [8], but we observed only peak shape distortions and retention time shifts due to lack of buffering capacity. No retention time shifts or peak shape distortions were observed with the 12.5-50 mM TEAB procedure (Table 1) when analysing QuPPe extracts.…”
Section: Matrices and Extraction Proceduresmentioning
confidence: 99%
See 2 more Smart Citations
“…It was found that the acidity of the extracts influenced the retention times and peak shapes if the QuPPe extracts (extracted with 1% formic acid in methanol) were analysed with < 1 mmol/L mobile phases. Poor recoveries have been reported for acidified QuPPe extracts [8], but we observed only peak shape distortions and retention time shifts due to lack of buffering capacity. No retention time shifts or peak shape distortions were observed with the 12.5-50 mM TEAB procedure (Table 1) when analysing QuPPe extracts.…”
Section: Matrices and Extraction Proceduresmentioning
confidence: 99%
“…IC based methods have been published where complex buffer suppression technology was used before the introduction of eluate into the ion source of the mass spectrometer . Dilution of the eluate with organic solvent after suppression increased detection sensitivity by a factor of three . The lowest validated LOQ was 10 µg/kg in food matrices and 5 µg/L in water .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…12 Ion chromatography, widely used for analysis of polar compounds, [13][14][15] was chosen as alternative technique to those indicates by EURLs for residue of pesticides in QuPPe method, 12 thanks to the recent and interesting developments in food analysis, if coupled with mass spectrometry. [16][17][18][19] Rajski et al, with their recent work, showed that it is possible to interface ion chromatography with high resolution mass spectrometry (IC-HRMS) by developing an analytical method for the determination of polar pesticides in fruit and vegetables. 16 Most recent scientific publications have highlighted the applicability of the IC-HRMS technique for the detection of some of these molecules in honey, thus giving a boost to the development of an alternative and functional analytical approach.…”
mentioning
confidence: 99%
“…[16][17][18][19] Rajski et al, with their recent work, showed that it is possible to interface ion chromatography with high resolution mass spectrometry (IC-HRMS) by developing an analytical method for the determination of polar pesticides in fruit and vegetables. 16 Most recent scientific publications have highlighted the applicability of the IC-HRMS technique for the detection of some of these molecules in honey, thus giving a boost to the development of an alternative and functional analytical approach. 20,21 The aim of this work was to verify the potential of IC-HRMS for the simultaneous determination of a complex group of…”
mentioning
confidence: 99%