2018
DOI: 10.1002/jssc.201701178
|View full text |Cite
|
Sign up to set email alerts
|

Coupling nanoliter high‐performance liquid chromatography to inductively coupled plasma mass spectrometry for arsenic speciation

Abstract: Nanoliter high-performance liquid chromatography shows low consumption of solvents and samples, offering one of the best choices for arsenic speciation in precious samples in combination with inuctively coupled plasma mass spectrometry. A systematic investigation on coupling nanoliter high-performance liquid chromatography to inductively coupled plasma mass spectrometry from instrument design to injected sample volume and mobile phase was performed in this study. Nanoflow mobile phase was delivered by flow spl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 30 publications
0
4
0
Order By: Relevance
“…Indeed, the accurate determination of heavy metals in cosmetics is important as they have a narrow range of safety between adequate amounts and excessive consumption. Among the various methods proposed for heavy metals analysis in cosmetic products, inductively coupled plasma mass spectrometry (ICP-MS) is the most frequently used due to its relative simplicity, low sample volume requirements, and low detection limits [72,73]. A method using microwave acid digestion, followed by ICP-MS determination for the analysis of heavy metal content in the henna and walnut tree bark samples was used for this study.…”
Section: Introductionmentioning
confidence: 99%
“…Indeed, the accurate determination of heavy metals in cosmetics is important as they have a narrow range of safety between adequate amounts and excessive consumption. Among the various methods proposed for heavy metals analysis in cosmetic products, inductively coupled plasma mass spectrometry (ICP-MS) is the most frequently used due to its relative simplicity, low sample volume requirements, and low detection limits [72,73]. A method using microwave acid digestion, followed by ICP-MS determination for the analysis of heavy metal content in the henna and walnut tree bark samples was used for this study.…”
Section: Introductionmentioning
confidence: 99%
“…One study presented a lower LOQ when using solid phase extraction (SPE) coupled to ET AAS, obtaining 0.006 μg L -1 in the determination of As(III) and As(V), but it should be noted that other species were not determined (Hassanpoor et al 2015). Using high performance liquid chromatography (HPLC) combined with ICP MS, Liu e Cai (2013) obtained values between 0.13 and 1.66 μg L -1 , Komorowicz and Barałkiewicz (2016) between 0.22 and 0.39 µg L -1 and Cheng et al (2018) between 3.00 and 5.90 μg L -1 for the determination of As III, As V, MMA, and DMA. Where in addition to the previous species, Komorowicz and Barałkiewicz (2016) also determined AsB and Liu and Cai (2013) quantified ROX and AsA.…”
Section: Resultsmentioning
confidence: 99%
“…In addition to total As quantification, speciation techniques are important to detect and quantify many of As species, which may occur in organic or inorganic forms and in different valence states, with implications on their bioavailability and toxicity (Abdul et al, 2015;Moe et al, 2016;Liu et al, 2018). Some hyphenated techniques consider chromatography and capillary electrophoresis (Khan et al, 2015;Ma et al, 2016;Cheng et al, 2018;García-Rico et al, 2019); ion chromatography (Zhu et al, 2017), ultraviolet spectroscopy and capillary electrophoresis (CE UV) (Lee et al, 2018) for the separation of species.…”
Section: Introductionmentioning
confidence: 99%
“…In this sense, methanol is more widely used than acetonitrile for RPC mobile phases [109,111]. Meanwhile, desolvation the liquid aerosol before it reaches the ICP, simple flow splitting after the HPLC column, or the use of a small bore or microbore column is also adopted to reduce the amount of organic solvent introduced into the detector [98,173,174].…”
Section: Detection Techniques For Speciation Analysismentioning
confidence: 99%