2009
DOI: 10.1002/bmc.1240
|View full text |Cite
|
Sign up to set email alerts
|

Coupling of solid‐phase microextraction with micellar desorption and high performance liquid chromatography for the determination of pharmaceutical residues in environmental liquid samples

Abstract: A residue analytical method combining solid-phase microextraction (SPME) with external micellar desorption (MD) and high-performance liquid chromatography with diode array detector (HPLC-DAD) has been developed and validated for the simultaneous determination of six pharmaceutical compounds, belonging to various therapeutic categories in water samples. Target compounds include antiinflamatory drugs (ibuprofen, ketoprofen and naproxen), an analgesic (phenazone), a lipid regulator (bezafibrate) and an antiepilep… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
4
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 30 publications
(6 citation statements)
references
References 35 publications
2
4
0
Order By: Relevance
“…Moreover, the precision of the method ( Table 5 ) is in agreement with values reported in the literature when working with SPME [ 11 , 17 , 20 , 21 , 23 , 26 , 27 ]. Likewise, comparing to previously developed methods coupling off-line SPME to CZE analysis, the intra-day reproducibility (approximately 10%) of the new proposed method herein, is not significantly different [ 19 , 43 , 44 ].…”
Section: Discussionsupporting
confidence: 88%
See 3 more Smart Citations
“…Moreover, the precision of the method ( Table 5 ) is in agreement with values reported in the literature when working with SPME [ 11 , 17 , 20 , 21 , 23 , 26 , 27 ]. Likewise, comparing to previously developed methods coupling off-line SPME to CZE analysis, the intra-day reproducibility (approximately 10%) of the new proposed method herein, is not significantly different [ 19 , 43 , 44 ].…”
Section: Discussionsupporting
confidence: 88%
“…Likewise, comparing to previously developed methods coupling off-line SPME to CZE analysis, the intra-day reproducibility (approximately 10%) of the new proposed method herein, is not significantly different [ 19 , 43 , 44 ]. It is worth noticing that such intra-day reproducibility values are also consistent with other coupled methods, i.e., SPME-HPLC or SPME-GC [ 20 , 21 , 23 ].…”
Section: Discussionsupporting
confidence: 81%
See 2 more Smart Citations
“…Miniaturized membrane-based microextraction techniques have been proposed for the extraction of NSAIDs and organic pollutants from various matrices. For instance, hollow-fiber liquid-phase microextraction (HF-LPME) [21], electromembrane extraction (EME) [22][23][24][25] and SPME [26] are proven to be beneficial in minimizing organic solvent usage. Nevertheless, analyzing the trace organic compound remains complex in complicated matrices and a wide range of chemical properties of the analytes, and they can be at concentrations as low as pg/mL in range [27,28].…”
Section: Introductionmentioning
confidence: 99%