2011
DOI: 10.1016/j.jmr.2011.07.013
|View full text |Cite
|
Sign up to set email alerts
|

CPMG echo amplitudes with arbitrary refocusing angle: Explicit expressions, asymptotic behavior, approximations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 15 publications
0
12
0
Order By: Relevance
“…These lead to significant errors, ranging up to as much as 50% to 100% of the true T 2 values when signal decay curves are fitted to a simple exponential . More accurate predictions can be obtained by using customized acquisition schemes and tailored analytical signal models or using algorithms that take into account the various factors that affect the spin dynamics in MSE sequences . In order to be compatible with the minimization of Eq.…”
Section: Methodsmentioning
confidence: 99%
“…These lead to significant errors, ranging up to as much as 50% to 100% of the true T 2 values when signal decay curves are fitted to a simple exponential . More accurate predictions can be obtained by using customized acquisition schemes and tailored analytical signal models or using algorithms that take into account the various factors that affect the spin dynamics in MSE sequences . In order to be compatible with the minimization of Eq.…”
Section: Methodsmentioning
confidence: 99%
“…In fact, this flip angle–dependent oscillatory behavior for multi‐spin‐echo sequences, such as the ones suggested by Carr and Purcell (CP) 13 or Meiboom and Gill (CPMG), 14 has already been demonstrated. 15 , 16 , 17 …”
Section: Introductionmentioning
confidence: 99%
“…The T 2,eff used for correction was determined as the effective T 2 decay obtained from a static LFA-CPMG experiment performed prior to each flow experiment. The use of an exponential convective decay model is based on the work by Petrova et al [ 34 ] that showed the asymptotic form of the T 2,eff -corrected signal in low flip angle CPMGs to be exponential. The exponential fit was validated to be a better fit to our data than the linear fit method that is applied in flow measurement using bulk CPMGs.…”
Section: Methodsmentioning
confidence: 99%
“…This flow map was presented as Figure 4 in Section 2. Flow experiments were performed using broadband excitation constant-gradient LFA-CPMG pulse sequences [33,34] using 45 • flip angle pulses of duration t pulse = 10 µs, and 2τ = 800 µs echo spacing. This pulse sequence is shown schematically in Figure 10.…”
Section: Methodsmentioning
confidence: 99%