2013
DOI: 10.1016/j.chroma.2013.03.025
|View full text |Cite
|
Sign up to set email alerts
|

Cross-linker effects on the separation efficiency on (poly)methacrylate capillary monolithic columns. Part II. Aqueous normal-phase liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
39
1
2

Year Published

2013
2013
2015
2015

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 44 publications
(42 citation statements)
references
References 48 publications
0
39
1
2
Order By: Relevance
“…In a recent study, we investigated the column-to-column reproducibility by comparing the retention data and bandwidths of various samples on nine different columns, prepared individually. The retention data demonstrated good repeatability (0.5-0.6 % for the nine DiEDMA columns and 0.6-1.3 % for the nine BIGDMA columns) [11]. The same results can be expected for gradually shortened columns preparing by subsequent cutting of short pieces.…”
Section: Resultsmentioning
confidence: 53%
See 2 more Smart Citations
“…In a recent study, we investigated the column-to-column reproducibility by comparing the retention data and bandwidths of various samples on nine different columns, prepared individually. The retention data demonstrated good repeatability (0.5-0.6 % for the nine DiEDMA columns and 0.6-1.3 % for the nine BIGDMA columns) [11]. The same results can be expected for gradually shortened columns preparing by subsequent cutting of short pieces.…”
Section: Resultsmentioning
confidence: 53%
“…However, the H-u plots (Eq. 2) are more shallow (show lower C-terms, characterizing less efficiency at higher flow rates of the mobile phase) in comparison to the ZIC-HILIC column, especially for weakly polar and non-polar samples (toluene, phenol [11].…”
Section: Resultsmentioning
confidence: 98%
See 1 more Smart Citation
“…The specific structure of the monomers resulted in monoliths with an increased microporosity and correspondingly increased contribution of SEC mechanism to polymer separation. Furthermore, the resolution achieved in the separation of the polystyrene standards considerably exceeds the values reported in the literature for similar monolithic columns [22,24]. The optimal structure of all monoliths regardless of the type of monomer used in preparation of monoliths was achieved using porogen consisting of nonanol as a poor solvent.…”
Section: Discussionmentioning
confidence: 84%
“…Using light scattering detection (LSD), it would be possible to distinguish between the cases, but detection cell volume of currently LSD incompatible with capillary columns used in the study. Anyway, the monolithic column prepared in this work can separate twice as much polystyrene standards in one run as the counterparts reported in the literature [22,24] and their almost linear calibration curves makes them attractive for the polymer analysis over broad range of molar mass.…”
Section: Resultsmentioning
confidence: 96%