Crown‐rump length audit plots with the use of operator‐specific PAPP‐A and β‐hCG median MoM

Abstract: In sonologists with more than 100 NT measurements, operator-specific PAPP-A and β-hCG median MoM plots are able to identify deviations potentially related to a systematic CRL bias. Systematic underestimation above 2 mm was observed in 1/5 of them. © 2016 John Wiley & Sons, Ltd.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0
1

Year Published

2020
2020
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 24 publications
0
7
0
1
Order By: Relevance
“…indicated a systematic CRL bias among 36% of the sonographers, and 60% of those had a CRL bias of more than 2 mm 21 .…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“…indicated a systematic CRL bias among 36% of the sonographers, and 60% of those had a CRL bias of more than 2 mm 21 .…”
Section: Discussionmentioning
confidence: 95%
“…Numerous studies have quantified measurement error variability in CRL in terms of limits of agreement, SDs of differences between operators, variance components and interclass correlation coefficients 13,14,21 . Results have been presented for intraobserver variation between measurements taken by the same sonographer and for interobserver variation between measurements taken by different sonographers.…”
Section: Distribution Of Crown-rump Length Measurement Errorsmentioning
confidence: 99%
“…Mathematical models [40,41] are implemented, and surveillance and prevention models will be offered. As will be further described in the methodology -the larger the risk, the earlier will be the GA at delivery, adding to the increase burden of prematurity [42][43][44][45][46][47][48][49][50].…”
Section: Methodsmentioning
confidence: 99%
“…Large-scale quantitative evaluation of CRL measurement quality based on the distribution of data is less challenging, with the drawback that reference biometric data are not available for comparative analyses, as it is the case of NT. Some authors have proposed to use specific deviations of biochemical markers (PAPP-A and βhCG), which are the result of systematic CRL measurement bias [20].…”
Section: Crl Measurement Quality Control Methodsmentioning
confidence: 99%