Cryoballoon Pressure Waveform Change during Balloon Inflation is not a Reliable Predictor of Adequate Pulmonary Vein Occlusion

Abstract: The change in pressure waveforms at the distal tip of inflated cryoballoon is not a reliable predictor of complete PV occlusion during cryoballoon ablation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(15 citation statements)
references
References 16 publications
0
15
0
Order By: Relevance
“…Some other techniques were tested to reduce or avoid contrast injection (in case of renal insufficiency, contrast media allergy, radiation exposure etc.) such as intracardiac echocardiography (ICE) 10 and transesophageal echocardiography color flow Doppler (TEE), 11 3D TEE 12 and charting the pressure waveform recordings at the cryoballoon (CB) tip during occlusion 13,14 …”
Section: Discussionmentioning
confidence: 99%
“…Some other techniques were tested to reduce or avoid contrast injection (in case of renal insufficiency, contrast media allergy, radiation exposure etc.) such as intracardiac echocardiography (ICE) 10 and transesophageal echocardiography color flow Doppler (TEE), 11 3D TEE 12 and charting the pressure waveform recordings at the cryoballoon (CB) tip during occlusion 13,14 …”
Section: Discussionmentioning
confidence: 99%
“…Initially, angiography constituted a method of confirming PV occlusion. However, due to the complications of radioiodine contrast, prolonged fluoroscopy times, and the frequent coexistence of chronic kidney disease in patients with AF, various predictors of PV occlusion and electrical isolation have been analyzed [8]. In 2009, Siklody et al introduced the transesophageal-Doppler-echocardiography (TEE)-guided cryoballoon apposition of PV and electrical isolation [4].…”
Section: Discussionmentioning
confidence: 99%
“…The study authors noticed that angiographic complete PV occlusion was detected in 43 of 67 PVs (64%) at the point when there was a change in the waveform from LA to PA. In the remaining 24 PVs, PV occlusion was completed with the adjustment of the cryoballoon under intracardiac echocardiographic guidance [8].…”
Section: Discussionmentioning
confidence: 99%
“…Hence, the PV occlusion assessment is of crucial value in CBA procedure. Currently, pulmonary venography is regarded as the standard criterion, although various alternatives have been proposed to reduce contrast or fluoroscopy use, such as intracardiac echocardiography (ICE) 16 , transesophageal echocardiography (TEE) 17,18 , and change of the pressure waveform recorded at the CB tip during occlusion 19,20 . Also, KODEX-EPD system is equipped with various tools for occlusion assessment 11,[21][22][23] .…”
Section: Occlusion Assessment Toolsmentioning
confidence: 99%