2008
DOI: 10.1016/s1507-1367(10)60092-2
|View full text |Cite
|
Sign up to set email alerts
|

CT-image based conformal high-dose-rate brachytherapy boost in the conservative treatment of stage I – II breast cancer – introducing the procedure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 12 publications
(14 citation statements)
references
References 31 publications
0
14
0
Order By: Relevance
“…5,[8][9][10][11][12][13][14][15]34 Later, HDR BT was also accepted as a safe alternative boost modality (Table 6). 4,6,7,12,[16][17][18][19][20][21][22][23][24][25][26][27]34 Only a few reports have compared the outcome in patients treated with BT or external beam boost. 6,7,[9][10][11][12][13][14][15]20,21,25,35,36 In the majority of these studies similar local control and cosmetic results have been reported for women boosted either with interstitial implants or electrons/photons.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…5,[8][9][10][11][12][13][14][15]34 Later, HDR BT was also accepted as a safe alternative boost modality (Table 6). 4,6,7,12,[16][17][18][19][20][21][22][23][24][25][26][27]34 Only a few reports have compared the outcome in patients treated with BT or external beam boost. 6,7,[9][10][11][12][13][14][15]20,21,25,35,36 In the majority of these studies similar local control and cosmetic results have been reported for women boosted either with interstitial implants or electrons/photons.…”
Section: Discussionmentioning
confidence: 99%
“…4,5,[8][9][10][11][12][13][14][15] Later, highdose-rate (HDR) BT has also been accepted as a safe alternative boost modality. 6,7,12,[16][17][18][19][20][21][22][23][24][25][26][27] …”
Section: Introductionmentioning
confidence: 99%
“…At present there are several techniques used in maintaining better coverage of the target volume. However, the irregular 3-D shape of the excision cavity and the normal tissue structures can only be accurately localized by visual information acquired from cross-sectional imaging (Kubaszewska et al, 2008). The use of surgical clips and CT at the same time seems to be the best method to determine the target volume, since both titanium clips and borders of the excision cavity can be visualized exactly from slice to slice (Polgar et al, 2000).…”
Section: Breast Cancermentioning
confidence: 99%
“…The skin dose should not exceed 60% of prescribed dose (executed only in case of a superficial plane implanted at least 10 mm from the skin). In the 3D treatment planning based on CT sectional-cross the main aspect is to achieve such dose distribution, where all surgical clips would receive at least 85 % of the prescribed dose (Kubaszewska et al, 2008). Planning concepts are based on the 3D reconstruction of the catheters, tumor bed clips maintaining proper distances (at least 10 mm) from critical structures (skin, ribs).…”
Section: Ct Based Treatment Planning Proceduresmentioning
confidence: 99%
See 1 more Smart Citation