2008
DOI: 10.1109/tie.2007.909084
|View full text |Cite
|
Sign up to set email alerts
|

Current-Fed Resonant Full-Bridge Boost DC/AC/DC Converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
29
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 87 publications
(29 citation statements)
references
References 14 publications
0
29
0
Order By: Relevance
“…The system design concerns the optimal operation point when the maximal energy value is transferred and the transistors control pulses have a maximal width and overlap. This operation mode was discussed deeply in the paper [11], and now only the guideline for its design is presenting. Relation between input I l and output i l converter [L] currents was expressed in [11] as:…”
Section: The Boost Operation Principlementioning
confidence: 99%
See 2 more Smart Citations
“…The system design concerns the optimal operation point when the maximal energy value is transferred and the transistors control pulses have a maximal width and overlap. This operation mode was discussed deeply in the paper [11], and now only the guideline for its design is presenting. Relation between input I l and output i l converter [L] currents was expressed in [11] as:…”
Section: The Boost Operation Principlementioning
confidence: 99%
“…This operation mode was discussed deeply in the paper [11], and now only the guideline for its design is presenting. Relation between input I l and output i l converter [L] currents was expressed in [11] as:…”
Section: The Boost Operation Principlementioning
confidence: 99%
See 1 more Smart Citation
“…Hence to eliminate this problem in control system the phase shift [9] [10] was introduced with the pulse width modulation. Also a bidirectional dc-dc converter [11]- [13] is realized by a current fed inverter on the low voltage side of the transformer and voltage fed inverter on the high voltage side of the transformer [14]- [16]. But all the conventional converters are pertaining to the dissatisfactions in terms of switching loss and inability to achieve zero voltage switching during wide load variations.…”
Section: Introductionmentioning
confidence: 99%
“…Besides the active methods, some passive methods have also been proposed. For example, LC resonance schemes have been studied in [17]- [19], which can also achieve soft switching of the main switches. However, its resonance energy can not be transferred to the load.…”
Section: Introductionmentioning
confidence: 99%