2015
DOI: 10.1109/temc.2014.2382556
|View full text |Cite
|
Sign up to set email alerts
|

Current Impulses in the Lightning Protection System of a Test House in Poland

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 26 publications
0
8
0
Order By: Relevance
“…3 together with the equivalent electrical diagrams of the test system. The detailed characteristics of the whole test site and test equipment used in the experimental investigations have been presented in [11].…”
Section: Test Sitementioning
confidence: 99%
See 1 more Smart Citation
“…3 together with the equivalent electrical diagrams of the test system. The detailed characteristics of the whole test site and test equipment used in the experimental investigations have been presented in [11].…”
Section: Test Sitementioning
confidence: 99%
“…Note that the ground resistivity of clay soil in Poland was almost two order of magnitude lower than for sandy soil at Camp Blanding (less than 100 m for clay soil versus 4000 m for sandy soil). Recent experimental results has been presented in detail in [11].…”
Section: Introductionmentioning
confidence: 99%
“…1 near to all symbols of groundings are the dc resistances of each ground rod or grounding system. The conductor (5) represented the uninsulated buried flat bar conductor connecting the ground rod (4) with the grounding system of supplying underground cable line (7). In addition at the open air test side they are connected with the PEN conductor of cable line at the cable termination box (6).…”
Section: The Proposed Model Of the Lpsmentioning
confidence: 99%
“…The International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida is one of the centres involved with this subject [1][2][3]. Similar studies are carried out at the Rzeszow University of Technology in a cooperation with ICLRT since 2007 [4][5][6][7][8]. There is a real scale simple model of residential house, located at the test side in Huta Poręby near Rzeszów, with dedicated LPS system connected to the electrical supplying installation.…”
Section: Introductionmentioning
confidence: 99%
“…The impact of lightning strikes on general buildings has been studied before [13][14][15][16]. In [13], the transient electric field was calculated inside a building struck by a lightning strike.…”
Section: Introductionmentioning
confidence: 99%