2008
DOI: 10.1590/s0100-39842008000400011
|View full text |Cite
|
Sign up to set email alerts
|

Curvas de isodose no ar em uma sala de mamografia

Abstract: OBJETIVO: O objetivo deste trabalho foi obter a distribuição da dose absorvida no ar numa sala de mamografia durante a simulação de um exame mamográfico, visando a reavaliar a necessidade do uso de barreiras de proteção radiológica nessas salas e a exposição das pacientes. MATERIAIS E MÉTODOS: Os dados da dose absorvida no ar foram coletados mediante simulação de exame mamográfico de um simulador de mama de BR12, em um equipamento Senograph 600T-Senix HF. Para tal, 158 pastilhas de CaSO4 foram distribuídas em … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 2 publications
0
2
0
1
Order By: Relevance
“…The absorbed dose distribution is represented by curves generated by points where the dose values are equal. Isodose curves are regular absorbed dose intervals drawn as depth dose distribution maps and can be expressed as a percentage of the absorbed dose at a reference point [2,18,25].…”
Section: Isodose Curvesmentioning
confidence: 99%
“…The absorbed dose distribution is represented by curves generated by points where the dose values are equal. Isodose curves are regular absorbed dose intervals drawn as depth dose distribution maps and can be expressed as a percentage of the absorbed dose at a reference point [2,18,25].…”
Section: Isodose Curvesmentioning
confidence: 99%
“…Adad et al have determined the isodose curve in a mammography room and concluded that the utilization of additional shielding at mammography rooms is not necessary, since at distances > 0.50 m, the measurements generated absorbed doses < 0.1 mGy per exposure ( 2 ) . Vieira et al (Determination of isodose curves in brachytherapy with linear radiation sources.…”
Section: Introductionmentioning
confidence: 99%
“… calibração e avaliação do desempenho de sistemas de imagens médicas; ; ; (HOFF, et. al., 2006)  desenvolvimento de programas de proteção radiológica e controle de qualidade destes equipamentos; ; (ADAD, et. al., 2008)  avaliação da qualidade da imagem; (PIRES, 2002); (PINA, et.…”
Section: Classificação E Aplicações Dos Simuladoresunclassified