2023
DOI: 10.1038/s41598-023-42451-0
|View full text |Cite
|
Sign up to set email alerts
|

Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5

Anna Golijanek-Jędrzejczyk,
Andrzej Mrowiec

Abstract: The paper presents the results of an experimental study of a cylindrical orifice with the orifice diameter ratio β = 0.5 and the flow opening length-to-diameter ratio L/d = 1, with hydraulic oil flowing in the DN50 measuring channel. The measurements of the values characterising the oil flow were made in the laminar flow regime, for the Reynolds numbers ranging between Re = 100 to 950. Based on the experimental tests, standard flow characteristics were created for four kinematic viscosity values in the range o… Show more