CYP2C9 Polymorphism Influence in PK/PD Model of Naproxen and 6-O-Desmethylnaproxen in Oral Fluid

Abstract: Polymorphisms in CYP2C9 can significantly interfere with the pharmacokinetic (PK) and pharmacodynamic (PD) parameters of nonsteroidal anti-inflammatory drugs (NSAIDs), including naproxen. The present research aimed to study the PK/PD parameters of naproxen and its metabolite, 6-O-desmethylnaproxen, associated with allelic variations of CYP2C9. In our study, a rapid, selective, and sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) method was developed and validated for the determination of nap… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
11
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(13 citation statements)
references
References 41 publications
1
11
0
Order By: Relevance
“…The MEPS methodology was selected for the extraction of analytes from oral fluid samples and calibration curves. MEPS consists of the miniaturization of conventional SPE with a conditioned needle incorporated directly into an injector syringe (Trajan Scientific Australia Pty Ltd) which is an alternative to other extraction methodologies in different matrixes [ 36 ], thus demonstrating its specificity and reduction in matrix effects [ 37 , 38 ], including in oral fluid samples [ 16 , 21 , 27 , 39 , 40 ].…”
Section: Experimental Designmentioning
confidence: 99%
See 4 more Smart Citations
“…The MEPS methodology was selected for the extraction of analytes from oral fluid samples and calibration curves. MEPS consists of the miniaturization of conventional SPE with a conditioned needle incorporated directly into an injector syringe (Trajan Scientific Australia Pty Ltd) which is an alternative to other extraction methodologies in different matrixes [ 36 ], thus demonstrating its specificity and reduction in matrix effects [ 37 , 38 ], including in oral fluid samples [ 16 , 21 , 27 , 39 , 40 ].…”
Section: Experimental Designmentioning
confidence: 99%
“…Finally, the syringe and BIN were washed (100 µL—5× MeOH) between each patient sample. The same process was performed for the calibration curve [ 21 , 27 , 38 ].…”
Section: Experimental Designmentioning
confidence: 99%
See 3 more Smart Citations