2014
DOI: 10.1109/jsen.2013.2296148
|View full text |Cite
|
Sign up to set email alerts
|

Data Fusion and Fault Diagnosis for Flexible Arrayed pH Sensor Measurement System Based on LabVIEW

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 25 publications
0
10
0
Order By: Relevance
“…[220][221][222] Data fusion and fault diagnosis can also help to improve the accuracy and reliability of the exible potentiometric pH sensing arrays based on RuO 2 sensitive electrodes and Ag differential REs. 223 Flexible sensing arrays can also facilitate spatial mapping of wound pH, which can reveal the location and severity of bacterial infections. For example, the simultaneous measurement of multiple sites within one wound region was made possible with an inexpensive exible array (3 cm  3 cm) of pH sensors on a palette paper substrate (Fig.…”
Section: Sensor Designs Suitable For Other Applicationsmentioning
confidence: 99%
“…[220][221][222] Data fusion and fault diagnosis can also help to improve the accuracy and reliability of the exible potentiometric pH sensing arrays based on RuO 2 sensitive electrodes and Ag differential REs. 223 Flexible sensing arrays can also facilitate spatial mapping of wound pH, which can reveal the location and severity of bacterial infections. For example, the simultaneous measurement of multiple sites within one wound region was made possible with an inexpensive exible array (3 cm  3 cm) of pH sensors on a palette paper substrate (Fig.…”
Section: Sensor Designs Suitable For Other Applicationsmentioning
confidence: 99%
“…The synthesized GO was characterized by Raman spectroscopy. Raman spectroscopy is an analytical technique for characterizing the differences between sp 2 and sp 3 hybridization in carbon materials [33]. The Raman spectra of GO are characterized by a D band at approximately 1340 cm −1 and a G band at approximately 1590 cm −1 [34,35].…”
Section: Raman Spectroscopy Of Go and Morphology Of Membranementioning
confidence: 99%
“…The voltage-time (V-T) measurement system used for this study was composed of a readout circuit, a data acquisition card (DAQ card, Model: NI USB-6201, National Instrument Corp., U.S.A.), and a computer with the LabVIEW program (Model: LabVIEW 2011, National Instrument Corp., U.S.A.) [29], [30]. The readout circuit is composed of six instrumentation amplifiers (LT1167, Analog Devices, Inc., U.S.A.).…”
Section: V-t Measurement Systemmentioning
confidence: 99%